文献速递乳腺MR

基于弥散张量成像的简化乳腺MRI在保乳术后患者中的临床价值

Clinical utility of abbreviated breast MRI based on diffusion tensor imaging in patients underwent breast conservative therapy.
PubMed 文献 · Radiol Med · 2023-02-10

前瞻性纳入47例保乳术后可触及肿块女性(62个病灶),比较两种1.5T简化乳腺MRI方案(AB-MRI 1不含DTI,AB-MRI 2加DTI),以组织病理为参考标准。DTI参数中MD的敏感度96.43%、特异度91.18%最高,DTI加入不显著增加采集时间并提高特异度。

要点

  • 保乳术后鉴别复发与术后改变,简化MRI加DTI可提高特异度。
  • DTI参数中MD敏感度96.43%、特异度91.18%,优于FA、AD、RD。
  • AB-MRI 2平均采集时间10分钟,仅比AB-MRI 1多约4分钟。

核心结论

  • DTI可纳入简化乳腺MRI方案,不显著增加采集时间,并提高保乳术后病灶鉴别的特异度和临床效用。

研究设计与样本

  • 前瞻性研究,经机构审查委员会批准,所有患者签署书面知情同意。
  • 纳入47例既往保乳术后可触及肿块的女性(平均年龄49岁,范围32-66岁),共62个乳腺病灶。
  • 采用1.5T MRI比较两种简化方案:AB-MRI 1(轴位T1、T2、增强前T1、第1次增强后及减影图像)和AB-MRI 2(相同序列加DTI)。
  • 两种方案均计算wash-in率,以组织病理学为参考标准。

诊断标准与关键数值

  • DTI参数MD的敏感度96.43%、特异度91.18%(P<0.001)。
  • FA敏感度78.57%、特异度88.24%;AD敏感度82.14%、特异度85.29%;RD敏感度85.71%、特异度79.41%(P<0.001)。
  • AB-MRI 1平均总采集时间6分钟、平均判读时间57.5秒;AB-MRI 2平均总采集时间10分钟、平均判读时间75秒。

临床应用与阅片要点

  • 在简化乳腺MRI方案中加入DTI,可在不明显延长采集时间的情况下提高保乳术后病灶鉴别的特异度。
  • MD在鉴别复发与术后改变中敏感度和特异度最高,可作为DTI参数中的优先观察指标。

局限性

  • 单中心前瞻性研究,样本量47例患者、62个病灶。
  • 仅使用1.5T MRI,未与其他场强设备比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the added value of the diffusion tensor imaging (DTI) parameters to abbreviated breast MRI protocol in differentiating recurrent breast cancer from post-operative changes in cases of breast conservative surgery (BCS).

METHODS: This prospective study was approved by our institutional review board. Written informed consent was obtained in all patients. 47 female patients (mean age, 49 years; range, 32-66 years) that previously underwent breast conservative surgery with a palpable mass were included in this study (62 breast lesions). Two abbreviated MRI protocols were compared using 1.5 Tesla MRI, AB-MRI 1 (axial T1, T2, pre-contrast T1, 1st post-contrast and subtracted images) and AB-MRI 2 (same sequences plus adding DTI). In both protocols, the wash-in rate was calculated. Histopathology was used as the standard of reference. Appropriate statistical tests were used to assess sensitivity, specificity, and diagnostic accuracy for each protocol.

RESULTS: The mean total acquisition time was of 6 min for AB-MRI 1 and 10 min for AB-MRI 2 protocols while the mean interpretation time was of 57.5 and 75 s, respectively. Among analyzed DTI parameters, MD (mean diffusivity) showed the highest sensitivity (96.43%) and specificity (91.18%) (P value = < 0.001). FA (fractional anisotropy), AD (axial diffusivity) and RD (radial diffusivity) showed sensitivity = (78.57%, 82.14% and 85.71%), specificity = (88.24, 85.29% and 79.41%), respectively, P value (< 0.001).

CONCLUSION: DTI may be included in abbreviated MRI protocols without a significant increase in acquisition time and with the advantage of increasing specificity and clinical utility in the characterization of post-conservative breast lesions.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Karam, Elmokadem, El-Rakhawy, et al. Clinical utility of abbreviated breast MRI based on diffusion tensor imaging in patients underwent breast conservative therapy. Radiol Med. 2023. PMID: 36763315. doi:10.1007/s11547-023-01600-1