PubMed 文献 · Eur J Radiol · 2023-02-03

本研究纳入67例女性(44个病灶),个体内比较使用CREST的乳腺DCE-MRI与既往无CREST的DCE-MRI。结果显示CREST显著减少心脏运动相关伪影、改善腋窝解剖结构和皮肤轮廓显示、减轻鬼影伪影,且不损害病灶清晰度;CREST效果在增强后极早期最明显。

要点

  • CREST可显著减少乳腺DCE-MRI中心脏运动相关伪影。
  • CREST改善腋窝解剖结构及皮肤轮廓显示并减轻鬼影伪影。
  • CREST不损害病灶清晰度,增强后极早期获益最明显。

关键影像表现/征象

  • 心脏运动相关伪影CREST-DCE显著低于conv-DCE(3.6±1.2 vs 2.1±0.8,p<0.001)。
  • 腋窝解剖结构显示CREST-DCE显著优于conv-DCE(3.9±1.0 vs 2.3±1.2,p<0.001)。
  • 皮肤轮廓显示CREST-DCE显著优于conv-DCE(4.3±0.8 vs 3.0±1.1,p<0.001)。
  • 鬼影伪影CREST-DCE显著轻于conv-DCE(3.8±1.1 vs 2.4±1.0,p<0.001)。
  • 胸骨旁区域两种技术可评估性相似(4.3±1.1 vs 4.2±1.2,p=0.47)。

诊断标准与关键数值

  • 图像质量参数及病灶清晰度采用五点Likert量表评估。
  • 直接比较中CREST-DCE图像评为「改善」54/67例、「等同」13/67例。
  • CREST效果在增强后极早期最明显(32/67例)。
  • 病灶清晰度CREST与conv-DCE评分相似(4.7±0.7 vs 4.8±0.2,p=0.18)。

临床应用与阅片要点

  • 乳腺DCE-MRI阅片时关注心脏运动相关伪影对腋窝及皮肤轮廓显示的影响。
  • CREST有助于改善增强后极早期图像质量,可辅助早期强化病灶的观察。
  • CREST不降低病灶清晰度,在需优化腋窝及皮肤显示时可考虑使用。

局限性

  • 本研究为个体内比较研究,样本量67例(44个病灶),未报告多中心数据。
  • 原文未报告研究是否回顾性或前瞻性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the effect of a cylindrical regional-suppression technique (CREST) on image quality and lesion conspicuity in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast.

METHOD: This was a comparative study of 67 women with 44 lesions who underwent breast DCE-MRI with CREST (CREST-DCE) and had a previous DCE-MRI without CREST (conv-DCE) available. Two radiologists assessed image quality parameters and lesion conspicuity using five-point Likert scales. In an intra-individual comparison, the effects of CREST on image quality (strong degradation to strong improvement) were assessed. Moreover, both radiologists identified the post-contrast phase, which benefited the most from using CREST in direct comparison. The statistical analysis included the Wilcoxon signed-rank test.

RESULTS: Cardiac motion-rated artefacts were significantly reduced in CREST-DCE compared to conv-DCE (3.6 ± 1.2 [CREST-DCE] vs 2.1 ± 0.8 [conv-DCE], p < 0.001). At the axilla, the visualisation of anatomical structures (3.9 ± 1.0 vs 2.3 ± 1.2, p < 0.001) and the skin contour (4.3 ± 0.8 vs 3.0 ± 1.1, p < 0.001) were significantly improved in CREST-DCE, whereas ghosting artefacts were significantly less pronounced (3.8 ± 1.1 vs 2.4 ± 1.0, p < 0.001). The parasternal region was similarly assessable using both techniques (4.3 ± 1.1 vs 4.2 ± 1.2, p = 0.47). In direct comparison, CREST-DCE images were classified as "improved" in 54/67 and "equivalent" in 13/67 exams. The effects of CREST were found to be most pronounced in the very early post-contrast phase (32/67). The lesion conspicuity was rated similar for CREST and conv-DCE (4.7 ± 0.7 vs 4.8 ± 0.2, p = 0.18).

CONCLUSIONS: CREST appears to be an effective tool to reduce cardiac motion-related artefacts and, therefore, may improve image quality in breast DCE-MRI without impairing lesion conspicuity.