六种超声风险分层系统对甲状腺结节的诊断效能:系统综述与网络荟萃分析
该系统综述与网络荟萃分析纳入39项研究共49661例患者,比较六种超声风险分层系统对甲状腺癌的诊断效能。各系统在最准确阈值下敏感度为64-77%、特异度为82-90%。网络荟萃分析显示ACR TI-RADS诊断效能最高,其次为K-TIRADS。
要点
- ACR TI-RADS在六种系统中诊断效能最高,其次为K-TIRADS。
- 各系统最准确阈值下敏感度64-77%、特异度82-90%。
- 最准确阈值:AACE/ACE/AME class 3、ACR TI-RADS TR5、EU-TIRADS 5、Kwak TIRADS 4c、K-TIRADS 5、ATA high suspicion。
核心结论
- 在六种超声风险分层系统中,ACR TI-RADS对甲状腺结节(甲状腺癌检测)的诊断效能最高,其次为K-TIRADS。
研究设计与样本
- 研究类型为系统综述与网络荟萃分析,检索五个文献数据库至2022年8月31日。
- 纳入39项研究共49661例患者,均为比较至少两种超声风险分层系统的研究。
- 参考标准为细胞学或组织学评估,偏倚风险采用Newcastle-Ottawa量表评价。
- 纳入系统包括AACE/ACE/AME、ACR TI-RADS、ATA、EU-TIRADS、K-TIRADS和Kwak TIRADS。
诊断标准与关键数值
- AACE/ACE/AME系统最准确阈值为class 3(高风险)。
- ACR TI-RADS最准确阈值为TR5(高度可疑)。
- EU-TIRADS最准确阈值为EU-TIRADS 5(高风险)。
- Kwak TIRADS最准确阈值为4c(中等关注但非典型恶性)。
- K-TIRADS最准确阈值为K-TIRADS 5(高度可疑),ATA系统为high suspicion。
临床应用与阅片要点
- 各系统最准确阈值下敏感度为64-77%、特异度为82-90%,可用于指导风险分层系统的选择与实施。
- 网络荟萃分析结果可辅助未来系统更新决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. Risk stratification systems for evaluating thyroid nodules on ultrasound use varying approaches to classify levels of suspicion for malignancy, leading to variable performance. OBJECTIVE. The purpose of this study was to perform a network meta-analysis comparing six risk stratification systems used to evaluate thyroid nodules on ultrasound in terms of their diagnostic performance for the detection of thyroid cancer. EVIDENCE ACQUISITION. Five bibliometric databases were searched for studies published through August 31, 2022, that compared at least two of six ultrasound risk stratification systems (the American Association of Clinical Endocrinologists, American College of Endocrinology, and Associazione Medici Endocrinologi [AACE/ACE/AME] system; American College of Radiology Thyroid Imaging Reporting and Data System [ACR TI-RADS]; the American Thyroid Association [ATA] risk stratification system; European Thyroid Association Thyroid Imaging Reporting and Data System [EU-TIRADS]; the Korean Thyroid Imaging Reporting and Data System [K-TIRADS] endorsed by the Korean Thyroid Association and the Korean Society of Thyroid Radiology; and the Thyroid Imaging Reporting and Data System developed by Kwak et al. [Kwak TIRADS]) in terms of their diagnostic performance for the detection of thyroid cancer, with cytologic or histologic evaluation used as a reference standard. The studies' risk of bias was evaluated using the Newcastle-Ottawa Scale. A meta-analysis of each system was performed to identify the risk category threshold that had the highest accuracy as well as the highest sensitivity and specificity at this threshold. Network meta-analysis was used to perform hierarchic ranking and identify the systems having the highest sensitivities and specificities at each system's most accurate threshold. EVIDENCE SYNTHESIS. The analysis included 39 studies with 49,661 patients. All studies were of fair (n = 17) or good (n = 22) quality. The most accurate risk category thresholds were class 3 (high risk) for the AACE/ACE/AME system, TR5 (highly suspicious) for ACR TI-RADS, EU-TIRADS 5 (high risk) for EU-TIRADS, 4c (moderate concern but not classic for malignancy) for Kwak TIRADS, K-TIRADS 5 (high suspicion) for K-TIRADS, and high suspicion for the ATA system. At these thresholds, the systems had sensitivity of 64-77% and specificity of 82-90%. Network meta-analysis identified the highest sensitivity and highest specificity for ACR TI-RADS, followed by K-TIRADS. CONCLUSION. Of six risk stratification systems, ACR TI-RADS had the highest diagnostic performance for the detection of thyroid nodules on ultrasound. CLINICAL IMPACT. This network meta-analysis can inform decisions regarding implementation of the risk stratification systems and can aid future system updates.
引用
- Kim, Kim, Basurrah, et al. Diagnostic Performance of Six Ultrasound Risk Stratification Systems for Thyroid Nodules: A Systematic Review and Network Meta-Analysis. AJR Am J Roentgenol. 2023. PMID: 36752367. doi:10.2214/AJR.22.28556
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。