COVID-19与疫苗接种对放射科的影响:基于剂量归档与通信系统的研究

COVID-19 and vaccination impact on radiology departments provided by Dose Archiving and Communication System.
PubMed 文献 · Eur Radiol · 2023-02-09

本研究利用集中式剂量归档与通信系统(DACS)回顾性分析27个放射中心86,136次胸部CT采集数据,评估COVID-19大流行不同阶段及疫苗接种对胸部CT实践和剂量的影响。结果显示前两波疫情期间胸部CT活动与疫情指标强相关,第三波疫苗接种率上升后相关性消失;低剂量方案仅占3.8%(基于CTDIvol)和4.3%(基于DLP)。

要点

  • 前两波疫情胸部CT量随疫情指标上升,第三波接种疫苗后该关联消失。
  • 仅3.8%(CTDIvol)和4.3%(DLP)的胸部CT采集可视为低剂量。
  • 公立与私立中心在第一波疫情中胸部CT活动与住院数相关性不同。

核心结论

  • 前两波COVID-19疫情期间胸部CT活动与疫情指标强正相关,疫苗接种后第三波该关联消失。
  • 低剂量胸部CT方案在分析期间仍占极少数(CTDIvol标准3.8%,DLP标准4.3%)。

研究设计与样本

  • 通过集中式剂量归档与通信系统(DACS)收集每日胸部CT活动及剂量学信息(DLP、CTDI、采集参数)。
  • 疫情指标(每日检测数、发病率、住院数)和疫苗接种率来自政府开放数据平台,采用描述性统计和相关分析。

诊断标准与关键数值

  • 第二波疫情期间每日胸部CT活动与住院数强正相关(R=0.7984,p<0.0001)。
  • 第一波疫情期间私立中心每日胸部CT活动与住院数呈负相关(-0.2819,p=0.0019)。
  • 第三波疫情期间每日胸部CT与每日发病率呈强负相关(R=-0.7939,p<0.0001)。
  • 低剂量CT判定:基于CTDIvol仅3.8%的采集为低剂量,基于DLP仅4.3%为低剂量。

临床应用与阅片要点

  • 疫情期间胸部CT需求随疫情指标波动,接种疫苗后需重新评估扫描量变化。
  • 低剂量方案使用率仍低,日常工作中可优化协议以增加低剂量应用。
  • 公立与私立中心在疫情不同阶段CT活动模式存在差异,需结合机构类型解读数据。

局限性

  • 回顾性研究设计可能存在数据收集偏倚。
  • 仅纳入27个中心,结果外推需谨慎。
  • 未报告其他潜在混杂因素(如患者特征、扫描指征)的调整分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To study the impact of COVID-19 on chest CT practice during the different waves using Dose Archiving and Communication System (DACS).

METHODS: Retrospective study including data from 86,136 chest CT acquisitions from 27 radiology centers (15 private; 12 public) between January 1, 2020, and October 13, 2021, using a centralized DACS. Daily chest CT activity and dosimetry information such as dose length product (DLP), computed tomography dose index (CTDI), and acquisition parameters were collected. Pandemic indicators (daily tests performed, incidence, and hospital admissions) and vaccination rates were collected from a governmental open-data platform. Descriptive statistics and correlation analysis were performed.

RESULTS: For the first two waves, strong positive and significant correlations were found between all pandemic indicators and total chest CT activity, as high as R = 0.7984 between daily chest CT activity and hospital admissions during the second wave (p < 0.0001). We found differences between public hospitals and private imaging centers during the first wave, with private centers demonstrating a negative correlation between daily chest CT activity and hospital admissions (-0.2819, p = 0.0019). Throughout the third wave, simultaneously with the rise of vaccination rates, total chest CT activity decreased with significant negative correlations with pandemic indicators, such as R = -0.7939 between daily chest CTs and daily incidence (p < 0.0001). Finally, less than 5% of all analyzed chest CTs could be considered as low dose.

CONCLUSIONS: During the first waves, COVID-19 had a strong impact on chest CT practice which was lost with the arrival of vaccination. Low-dose protocols remained marginal.

KEY POINTS: • There was a significant correlation between the number of daily chest CTs and pandemic indicators throughout the first two waves. It was lost during the third wave due to vaccination arrival. • Differences were observed between public and private centers, especially during the first wave, less during the second, and were lost during the third. • During the first three waves of COVID-19 pandemic, few CT helical acquisitions could be considered as low dose with only 3.8% of the acquisitions according to CTDIvol and 4.3% according to DLP.

来源:Eur Radiol,查看原文。版权归原作者所有。