文献速递儿科影像胸部MR

儿科胸部MRI肺实质与结构显示:不同短回波与超短回波序列方案比较

Lung parenchyma and structure visualisation in paediatric chest MRI: a comparison of different short and ultra-short echo time protocols.
PubMed 文献 · Clin Radiol · 2023-01-20

研究在1.5T MRI上比较多种短/超短回波序列在儿童及健康志愿者中的肺成像质量,纳入囊性纤维化患儿、早产儿及健康志愿者。前瞻性ZTE3D与UTE3D图像质量最佳,回顾性ZTE4D未达诊断质量且伪影可模拟肺病变。

要点

  • 前瞻性ZTE3D与UTE3D在儿童和志愿者中图像质量最佳。
  • ZTE4D回顾性重建未达诊断质量,伪影可模拟肺病变。
  • ZTE3D vnav图像质量可靠,但扫描时间依赖导航触发效率。

核心结论

  • 前瞻性ZTE3D和UTE3D读出的图像质量在儿童与志愿者中均最佳。
  • 当前回顾性ZTE3D读出(ZTE4D)未提供诊断级图像质量,且引入可模拟肺病变的伪影。

研究设计与样本

  • 研究纳入8例囊性纤维化患者(中位14岁,范围13-17岁)、7例早产儿伴或不伴支气管肺发育不良(中位10岁,范围10-11岁)及10名健康志愿者(中位32岁,范围20-52岁)。
  • 使用1.5T MRI系统,采集吸气末和呼气末3D SPGR3D、3D ZTE3D、自由呼吸3D UTE3D、前瞻性投影导航径向ZTE3D(ZTE3D vnav)及4D ZTE(ZTE4D)。
  • 定量评估计算对比噪声比(CNR)和信噪比(SNR),定性评分评估肺内血管、叶间裂、支气管显示、图像噪声、伪影及整体可接受性。

关键影像表现/征象

  • 定性评分评估肺内血管、叶间裂、支气管、图像噪声、伪影及整体可接受性。
  • ZTE4D引入的伪影分布于整个成像容积,可模拟肺病变。

临床应用与阅片要点

  • 儿童胸部MRI肺成像优先选择前瞻性ZTE3D或UTE3D序列以获得最佳图像质量。
  • 使用ZTE4D时需警惕其伪影可模拟肺病变,避免误判。
  • ZTE3D vnav图像质量可靠,但需考虑导航触发效率和呼吸模式对扫描时间的影响。

局限性

  • ZTE3D vnav扫描时间高度依赖导航触发效率和呼吸模式。
  • 样本量小,包括8例CF患者、7例早产儿和10名健康志愿者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate image quality acquired at lung imaging using magnetic resonance imaging (MRI) sequences using short and ultra-short (UTE) echo times (TEs) with different acquisition strategies (breath-hold, prospective, and retrospective gating) in paediatric patients and in healthy volunteers.

MATERIALS AND METHODS: End-inspiratory and end-expiratory three-dimensional (3D) spoiled gradient (SPGR3D) and 3D zero echo-time (ZTE3D), and 3D UTE free-breathing (UTE3D), prospective projection navigated radial ZTE3D (ZTE3D vnav), and four-dimensional ZTE (ZTE4D) were performed using a 1.5 T MRI system. For quantitative assessment, the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) values were calculated. To evaluate image quality, qualitative scoring was undertaken on all sequences to evaluate depiction of intrapulmonary vessels, fissures, bronchi, imaging noise, artefacts, and overall acceptability.

RESULTS: Eight cystic fibrosis (CF) patients (median age 14 years, range 13-17 years), seven children with history of prematurity with or without bronchopulmonary dysplasia (BPD; median 10 years, range 10-11 years), and 10 healthy volunteers (median 32 years, range 20-52 years) were included in the study. ZTE3D vnav provided the most reliable output in terms of image quality, although scan time was highly dependent on navigator triggering efficiency and respiratory pattern.

CONCLUSIONS: Best image quality was achieved with prospective ZTE3D and UTE3D readouts both in children and volunteers. The current implementation of retrospective ZTE3D readout (ZTE4D) did not provide diagnostic image quality but rather introduced artefacts over the entire imaging volume mimicking lung pathology.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Papp, Elders, Wielopolski, et al. Lung parenchyma and structure visualisation in paediatric chest MRI: a comparison of different short and ultra-short echo time protocols. Clin Radiol. 2023. PMID: 36746723. doi:10.1016/j.crad.2022.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。