文献速递神经MR

单指数、双指数扩散加权成像与三维伪连续动脉自旋标记无创评估胶质瘤分级及IDH突变状态

Noninvasively evaluating the grade and IDH mutation status of gliomas by using mono-exponential, bi-exponential diffusion-weighted imaging and three-dimensional pseudo-continuous arterial spin labeling.
PubMed 文献 · Eur J Radiol · 2023-02-01

本研究纳入95例病理证实的2-4级胶质瘤患者,术前行DWI、IVIM及3D pCASL检查。结果显示HGG的ADCmean、ADCmin、Dmean、Dmin低于LGG,而CBFmean、CBFmax高于LGG;CBFmax联合Dmin鉴别LGG与HGG的AUC达0.906,预测IDH突变状态的AUC达0.938。

要点

  • CBFmax联合Dmin可高效鉴别高低级别胶质瘤,AUC 0.906。
  • Dmin单独鉴别高低级别胶质瘤AUC 0.878,优于Dmean和CBFmax。
  • CBFmax联合Dmin预测IDH突变状态AUC 0.938,敏感度92.9%、特异度95.5%。

关键影像表现/征象

  • HGG的ADCmean、ADCmin、Dmean、Dmin值低于LGG。
  • HGG的CBFmean、CBFmax值高于LGG。
  • 在2级和3级弥漫性星形细胞瘤中,IDH突变型与野生型的ADCmin、Dmean、Dmin、CBFmean、CBFmax差异有统计学意义。

诊断标准与关键数值

  • Dmean、Dmin、CBFmax鉴别LGG与HGG的AUC分别为0.827、0.878、0.839。
  • CBFmax联合Dmin鉴别LGG与HGG的AUC为0.906,敏感度82.4%,特异度86.4%。
  • CBFmax联合Dmin预测IDH突变状态的AUC为0.938,敏感度92.9%,特异度95.5%。

临床应用与阅片要点

  • 可将IVIM参数Dmin与3D pCASL参数CBFmax联合用于术前无创评估胶质瘤级别和IDH突变状态。
  • ADCmin、Dmean、Dmin、CBFmean、CBFmax在IDH突变预测中均有价值,其中Dmin和CBFmax联合效能最高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To noninvasively assess the diagnostic performance of diffusion-weighted imaging (DWI), bi-exponential intravoxel incoherent motion imaging (IVIM) and three-dimensional pseudo-continuous arterial spin labeling (3D pCASL) in differentiating lower-grade gliomas (LGGs) from high-grade gliomas (HGGs), and predicting the isocitrate dehydrogenase (IDH) mutation status.

MATERIALS AND METHODS: Ninety-five patients with pathologically confirmed grade 2-4 gliomas with preoperative DWI, IVIM and 3D pCASL were enrolled in this study. The Student's t test and Mann-Whitney U test were used to evaluate differences in parameters of DWI, IVIM and 3D pCASL between LGG and HGG as well as between mutant and wild-type IDH in grade 2 and 3 diffusion astrocytoma; receiver operator characteristic (ROC) analysis was used to assess the diagnostic performance.

RESULTS: The value of ADCmean, ADCmin, Dmean and Dmin in HGGs were lower than in LGGs, while the value of CBFmean and CBFmax in HGGs were higher than in LGGs. In ROC analysis, the AUC values of Dmean, Dmin and CBFmax were 0.827, 0.878 and 0.839, respectively. The combination of CBFmax and Dmin displayed the highest diagnostic performance to distinguish LGGs from HGGs, with AUC 0.906, sensitivity 82.4 %, and specificity 86.4 %. In grades 2 and 3 diffusion astrocytoma patients, ADCmin, Dmean, Dmin, CBFmean and CBFmax showed significant differences between IDHmut and IDHwt group (p < 0.05, 0.001, 0.001, 0.01 and 0.001, respectively) and the AUC values were 0. 709, 0.849, 0.919, 0.755 and 0.873, respectively. Similarly, the combination of CBFmax and Dmin demonstrated the highest AUC value (0.938) in prediction IDH mutation status, with sensitivity 92.9 %, and specificity 95.5 %.

CONCLUSION: The combination of IVIM and 3D pCASL can be used in prediction histologic grade and IDH mutation status of glioma noninvasively.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Guo, Jiang. Noninvasively evaluating the grade and IDH mutation status of gliomas by using mono-exponential, bi-exponential diffusion-weighted imaging and three-dimensional pseudo-continuous arterial spin labeling. Eur J Radiol. 2023. PMID: 36738600. doi:10.1016/j.ejrad.2023.110721

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。