文献速递神经US

低强度超声通过上调磷酸化内皮型一氧化氮合酶减小小鼠大脑中动脉闭塞模型脑梗死体积

Low-Intensity Ultrasound Reduces Brain Infarct Size by Upregulating Phosphorylated Endothelial Nitric Oxide in Mouse Model of Middle Cerebral Artery Occlusion.
PubMed 文献 · Ultrasound Med Biol · 2023-02-02

研究在小鼠大脑中动脉闭塞模型中探讨低强度超声的治疗效果,发现特定频率和声压的超声可显著减小梗死体积,其神经保护作用与调节磷酸化内皮型一氧化氮合酶相关,且不依赖脑血流量变化。

要点

  • 低强度超声(0.25 MHz、2.0 MPa)使皮层梗死体积减小4倍,纹状体减小1.5倍,大脑半球减小3.5倍。
  • 超声治疗不增加脑血流量,但上调p-eNOS-S1177并下调p-eNOS-T494。
  • 组织病理学未见出血、炎症或坏死证据,提示安全性良好。

关键影像表现/征象

  • 组I中两种频率和多数声压的超声均减小梗死体积,最佳为0.25 MHz、2.0 MPa。
  • 与对照组相比,最佳参数下皮层梗死体积减小4倍,尾状壳核减小1.5倍,大脑半球减小3.5倍。
  • 组III中超声仅引起脑血流量轻微增加,但p-eNOS-S1177增加2.6倍,p-eNOS-T494相应减少。
  • 组织病理学未见出血、炎症或坏死证据。

诊断标准与关键数值

  • 梗死体积在MCAO后24小时测量。
  • 组II中测量梗死体积与风险区比值。
  • 超声参数:频率0.25和1.05 MHz,每种频率三个不同声压,最佳为0.25 MHz、2.0 MPa。

临床应用与阅片要点

  • 低强度超声可能作为急性缺血性卒中的神经保护治疗手段,但尚未应用于临床。
  • 其作用机制与调节p-eNOS磷酸化相关,独立于脑血流改变。
  • 需注意超声参数(频率和声压)对治疗效果的关键影响。

局限性

  • 研究为小鼠模型,结果不能直接外推至人类。
  • 样本量有限,尤其组II仅11只小鼠。
  • 未报告随机化、盲法等实验设计细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: There have been attempts to use therapeutic ultrasound (US) for the treatment of both experimental and clinical stroke. We hypothesized that low-intensity US has direct beneficial effects on the brain independent of cerebral blood flow (CBF) during middle cerebral artery occlusion (MCAO).

METHODS: Three groups of mice were studied. Group I included 84 mice with MCAO undergoing US treatment/no treatment at two US frequencies (0.25 and 1.05 MHz) with three different acoustic pressures at each frequency in which infarct size (IS) was measured 24 h later. Group II included 11 mice undergoing treatment based on best US results from group I animals in which the IS/risk area (RA) ratio was measured 24 h later. Group III included 38 normal mice undergoing US treatment/no treatment for assessment of CBF, tissue metabolite and protein expression and histopathology.

DISCUSSION: Ultrasound at both frequencies and most acoustic pressures resulted in reduction in IS in group I animals, with the best results obtained with 0.25 MHz at 2.0 MPa: IS was reduced 4-fold in the cerebral cortex, 1.5-fold in the caudate putamen and 3.5-fold in the cerebral hemisphere compared with control. US application in group III animals elicited only a marginal increase in CBF despite a 2.6-fold increase in phosphorylated endothelial nitric oxide synthase (p-eNOS)-S1177 and a corresponding decrease in p-eNOS-T494. Histopathology revealed no evidence of hemorrhage, inflammation or necrosis.

CONCLUSION: Low-intensity US at specific frequencies and acoustic pressures results in marked neuroprotection in a mouse model of stroke by modulation of p-eNOS independent of its effect on CBF.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Davis, Ammi, Zhu, et al. Low-Intensity Ultrasound Reduces Brain Infarct Size by Upregulating Phosphorylated Endothelial Nitric Oxide in Mouse Model of Middle Cerebral Artery Occlusion. Ultrasound Med Biol. 2023. PMID: 36739244. doi:10.1016/j.ultrasmedbio.2022.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。