改良动态CT脊髓造影检测1型和2型脑脊液漏的操作方法
该回顾性研究比较了传统与改良动态CT脊髓造影在检测1型和2型脑脊液漏时的辐射剂量。改良技术采用单次扫描采集、减少对比剂用量和缩小扫描覆盖范围,使平均总有效剂量从31.3 mSv降至15.1 mSv,差异有统计学意义。
要点
- 改良动态CT脊髓造影可显著降低1型和2型脑脊液漏检测的辐射剂量。
- 改良技术通过单次扫描采集、减少对比剂用量和缩小扫描覆盖范围实现。
- 传统动态CT脊髓造影平均采集3.6次,改良组平均2.8次。
关键影像表现/征象
- 传统动态CT脊髓造影组25例,平均采集3.6次,平均总有效剂量31.3 mSv(范围11.3-68.4 mSv)。
- 改良动态CT脊髓造影组12例,平均采集2.8次,平均总有效剂量15.1 mSv(范围4.8-24.6 mSv)。
诊断标准与关键数值
- 1型脑脊液漏为硬膜撕裂所致,2型为脑膜憩室破裂所致。
- 两组间有效剂量和剂量长度乘积差异有统计学意义(P < .0001和P = .01)。
临床应用与阅片要点
- 在怀疑1型或2型脑脊液漏时,可考虑采用改良动态CT脊髓造影以减少辐射剂量。
- 操作时注意单次扫描采集、减少对比剂用量和缩小扫描覆盖范围。
局限性
- 回顾性研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Dynamic CT myelography can identify spinal CSF leaks secondary to dural tears (type 1) and ruptured meningeal diverticula (type 2), but the radiation can be high secondary to multiple successive acquisitions. The purpose of this article is to discuss the procedural approach of a modified dynamic CT myelography technique with single scan acquisitions, reduced contrast volume, and condensed scan coverage and compare its radiation dose with that in traditional dynamic CT myelography.
MATERIALS AND METHODS: Retrospective review was performed for patients with spontaneous CSF leaks showing extradural collections on spine MR imaging who underwent traditional and modified dynamic CT myelography. The radiation doses between the 2 cohorts were compared.
RESULTS: Thirty-seven patients (25 women, 12 men) had a type 1 or 2 CSF leak on dynamic CT myelography. Thirty-one patients had a type 1 CSF leak, and 6 patients had type 2 leaks. The traditional dynamic CT myelography was performed in 25 patients, and the average number of acquisitions per dynamic CT myelography was 3.6. The mean total effective dose per dynamic CT myelography was 31.3 mSv (range, 11.3-68.4 mSv). The modified dynamic CT myelography was performed in 12 patients, and the average number of acquisitions was 2.8. The mean total effective dose per dynamic CT myelography was 15.1 mSv (range, 4.8-24.6 mSv). The effective dose and dose-length product between the cohorts were statistically significant (P < .0001 and .01, respectively).
CONCLUSIONS: Modified dynamic CT myelography performed with single scan acquisitions, smaller volume of contrast, and reduced scan coverage can reduce the radiation dose for type 1 and 2 CSF leak detection.
引用
- Mamlouk, Shen, Dahlin, et al. Modified Dynamic CT Myelography for Type 1 and 2 CSF Leaks: A Procedural Approach. AJNR Am J Neuroradiol. 2023. PMID: 36732032. doi:10.3174/ajnr.A7784