文献速递骨肌CT

超低剂量CT可用于金属植入物患者的下肢扭转测量

Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants.
PubMed 文献 · Br J Radiol · 2023-02-14

回顾性纳入102例需下肢扭转测量且扫描野内有金属植入物的患者,采用超低剂量CT协议(自动管电流和管电压,参考设置髋100kV/20mAs、膝80kV/20mAs、踝80kV/10mAs),两位放射科医生独立测量股骨颈前倾角、胫骨、膝关节内及整体腿扭转,结果一致性好(最大扭转差异4.1°),诊断信心高(92.2%和93.1%评为5/5),中位总剂量长度乘积16.5mGycm。结论认为该协议在金属植入物患者中可行。

要点

  • 超低剂量CT协议可用于金属植入物患者的下肢扭转测量,辐射剂量低。
  • 两位读者测量扭转的最大差异仅4.1°,一致性好。
  • 92.2%–93.1%的病例诊断信心评为5/5,最差为3/5。

局限性

  • 回顾性研究设计。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Patients who need torsion measurement of the lower limb often have metal implants hindering e.g. MRI. A new ultra-low-dose (ULD-)CT protocol might be feasible for torsion measurement at cost of relatively low radiation exposure.

METHODS: We retrospectively included all patients with clinically indicated torsion measurement in the period July 2019 to June 2021 and metal implants in the scanning field. The ULD-CT protocol comprised automated tube current time product and automated tube voltage with reference settings of 100kV/20mAs (hip), 80kV/20mAs (knee) and 80kV/10mAs (ankle). Femoral neck anteversion, tibial, intra-articular knee and overall leg torsion measurements were performed by two radiologists independently. Diagnostic confidence regarding the delineation of the relevant cortical bone was rated on a 5-point Likert scale (1 = non-diagnostic, 5 = excellent).

RESULTS: 102 consecutive patients could be included (BMI 27.38 ± 5.85) with 154 metal implants. Median total dose length product of the ULD-CT-torsion measurement was 16.5mGycm [11-39]. Both readers showed high agreement with a maximum torsional difference of 4.1°. Diagnostic confidence was rated best (5/5) in 92.2% (reader 1) and 93.1% (reader 2) with a worst rating of 3/5.

CONCLUSION: The new ULD-CT protocol is feasible for torsion measurement of the lower limb - even in patients with metal implants.

ADVANCES IN KNOWLEDGE: Metal implants are not an obstacle for ULD-CT torsion measurements of the lower limb.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Keller, Grünwald, Springer, et al. Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants. Br J Radiol. 2023. PMID: 36728237. doi:10.1259/bjr.20220495