文献速递技术与安全CT

重复对比增强显微CT检查降低动物福利并影响肿瘤生理

Repeated Contrast-Enhanced Micro-CT Examinations Decrease Animal Welfare and Influence Tumor Physiology.
PubMed 文献 · Invest Radiol · 2022-10-25

该研究将4T1乳腺癌小鼠分为5组(无成像、仅麻醉、4 mGy CT、50 mGy CT、CE-CT),每组半数接受瑞戈非尼治疗,1周内成像3次。结果显示麻醉和CT成像增加动物负担,CE-CT联合治疗显著降低运动协调性;CT扫描组肿瘤灌注增高、细胞增殖降低,CE-CT组差异最显著。

要点

  • 重复CE-CT可损害动物运动协调性,影响动物福利。
  • 重复CT协议可诱导肿瘤生理改变:灌注增高、增殖降低。
  • 临床前肿瘤研究中需考虑CT成像对肿瘤生理的潜在影响。

核心结论

  • 重复(对比增强)CT成像可导致麻醉动物运动协调性受损,从而影响动物福利。
  • 标准CT协议重复应用可诱导肿瘤生理改变,包括肿瘤灌注增高和细胞增殖降低。
  • 对比增强CT组的差异最为显著,临床前肿瘤研究中应仔细考虑这些潜在效应。

研究设计与样本

  • 研究类型为动物实验,使用4T1乳腺癌荷瘤小鼠。
  • 小鼠分为5组:无成像、仅异氟烷麻醉、4 mGy CT、50 mGy CT、CE-CT(iomeprol)。
  • 每组半数接受多激酶抑制剂瑞戈非尼治疗。
  • 1周内进行3次成像,均使用异氟烷麻醉。

关键影像表现/征象

  • 评分表显示麻醉后动物负担增加,联合CT成像后更高(P < 0.001)。
  • 平扫CT未影响运动协调性,但CE-CT联合肿瘤治疗显著降低运动协调性(P < 0.001)。
  • 肿瘤生长和血管密度未受麻醉或成像影响。
  • CT扫描动物肿瘤灌注增高(P < 0.001)、肿瘤细胞增殖降低(P < 0.001),两种辐射剂量均如此。
  • 对照组与CE-CT组之间差异最显著。

临床应用与阅片要点

  • 临床前肿瘤纵向研究中使用重复CT(尤其CE-CT)时,应关注对动物福利和肿瘤生理的潜在影响。
  • 解读临床前CT肿瘤灌注和增殖数据时,需考虑成像本身可能导致的生理改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Computed tomography (CT) imaging is considered relatively safe and is often used in preclinical research to study physiological processes. However, the sum of low-dose radiation, anesthesia, and animal handling might impact animal welfare and physiological parameters. This is particularly relevant for longitudinal studies with repeated CT examinations. Therefore, we investigated the influence of repeated native and contrast-enhanced (CE) CT on animal welfare and tumor physiology in regorafenib-treated and nontreated tumor-bearing mice.

MATERIAL AND METHODS: Mice bearing 4T1 breast cancer were divided into 5 groups: (1) no imaging, (2) isoflurane anesthesia only, (3) 4 mGy CT, (4) 50 mGy CT, and (5) CE-CT (iomeprol). In addition, half of each group was treated with the multikinase inhibitor regorafenib. Mice were imaged 3 times within 1 week under isoflurane anesthesia. Behavioral alterations were investigated by score sheet evaluation, rotarod test, heart rate measurements, and fecal corticosterone metabolite analysis. Tumor growth was measured daily with a caliper. Tumors were excised at the end of the experiment and histologically examined for blood vessel density, perfusion, and cell proliferation.

RESULTS: According to the score sheet, animals showed a higher burden after anesthesia administration and in addition with CT imaging ( P < 0.001). Motor coordination was not affected by native CT, but significantly decreased after CE-CT in combination with the tumor therapy ( P < 0.001). Whereas tumor growth and blood vessel density were not influenced by anesthesia or imaging, CT-scanned animals had a higher tumor perfusion ( P < 0.001) and a lower tumor cell proliferation ( P < 0.001) for both radiation doses. The most significant difference was observed between the control and CE-CT groups.

CONCLUSION: Repeated (CE-) CT imaging of anesthetized animals can lead to an impairment of animal motor coordination and, thus, welfare. Furthermore, these standard CT protocols seem to be capable of inducing alterations in tumor physiology when applied repetitively. These potential effects of native and CE-CT should be carefully considered in preclinical oncological research.