加速液体与白质抑制成像准确诊断多发性硬化皮层及幕下病灶
前瞻性3T扫描回顾性分析42例多发性硬化患者,比较CS-FLAWS与PSIR联合3D DIR对皮层及幕下病灶的分类诊断效能。CS-FLAWS检出的皮层病灶(263 vs 251)和幕下病灶(123 vs 109)数量与PSIR无显著差异,但假阴性更少(皮层1 vs 13,幕下1 vs 15,P<0.01),诊断置信度高,全脑扫描仅需5分15秒。
要点
- CS-FLAWS在3T下对MS皮层和幕下病灶的检出与PSIR相当,且假阴性更少。
- CS-FLAWS全脑扫描时间约5分15秒,适合临床常规MS全脑评估。
- 联合3D DIR可提高皮层和幕下病灶分类的可靠性。
关键影像表现/征象
- CS-FLAWS检出皮层病灶263个,PSIR检出251个(P=0.74)。
- CS-FLAWS检出幕下病灶123个,PSIR检出109个(P=0.63)。
- CS-FLAWS皮层病灶假阴性1个,PSIR假阴性13个(P<0.01)。
- CS-FLAWS幕下病灶假阴性1个,PSIR假阴性15个(P<0.01)。
- 两种序列均无假阳性发现,各对比诊断置信度均高。
临床应用与阅片要点
- 日常阅片可采用3D CS-FLAWS联合3D DIR评估MS皮层及幕下病灶,减少漏诊。
- CS-FLAWS扫描时间约5分15秒,适合纳入MS全脑常规协议。
- 注意皮层病灶与近皮层病灶的区分,CS-FLAWS假阴性少有助于分类。
局限性
- 回顾性分析设计。
- 单中心研究,样本量42例。
- 仅纳入3T扫描数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The precise location of multiple sclerosis (MS) cortical lesions can be very challenging at 3 T, yet distinguishing them from subcortical lesions is essential for the diagnosis and prognosis of the disease. Compressed sensing-accelerated fluid and white matter suppression imaging (CS-FLAWS) is a new magnetic resonance imaging sequence derived from magnetization-prepared 2 rapid acquisition gradient echo with promising features for the detection and classification of MS lesions. The objective of this study was to compare the diagnostic performances of CS-FLAWS (evaluated imaging) and phase sensitive inversion recovery (PSIR; reference imaging) for classification of cortical lesions (primary objective) and infratentorial lesions (secondary objective) in MS, in combination with 3-dimensional (3D) double inversion recovery (DIR).
MATERIALS AND METHODS: Prospective 3 T scans (MS first diagnosis or follow-up) acquired between March and August 2021 were retrospectively analyzed. All underwent 3D CS-FLAWS, axial 2D PSIR, and 3D DIR. Double-blinded reading sessions exclusively in axial plane and final consensual reading were performed to assess the number of cortical and infratentorial lesions. Wilcoxon test was used to compare the 2 imaging datasets (FLAWS + DIR and PSIR + DIR), and intraobserver and interobserver agreement was assessed using the intraclass correlation coefficient.
RESULTS: Forty-two patients were analyzed (38 with relapsing-remitting MS, 29 women, 42.7 ± 12.6 years old). Compressed sensing-accelerated FLAWS allowed the identification of 263 cortical lesions versus 251 with PSIR ( P = 0.74) and 123 infratentorial lesions versus 109 with PSIR ( P = 0.63), corresponding to a nonsignificant difference between the 2 sequences. Compressed sensing-accelerated FLAWS exhibited fewer false-negative findings than PSIR either for cortical lesions (1 vs 13; P < 0.01) or infratentorial lesions (1 vs 15; P < 0.01). No false-positive findings were found with any of the 2 sequences. Diagnostic confidence was high for each contrast.
CONCLUSION: Three-dimensional CS-FLAWS is as accurate as 2D PSIR imaging for classification of cortical and infratentorial MS lesions, with fewer false-negative findings, opening the way to a reliable full brain MS exploration in a clinically acceptable duration (5 minutes 15 seconds).
引用
- Martin, Emorine, Megdiche, et al. Accurate Diagnosis of Cortical and Infratentorial Lesions in Multiple Sclerosis Using Accelerated Fluid and White Matter Suppression Imaging. Invest Radiol. 2022. PMID: 36730698. doi:10.1097/RLI.0000000000000939
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。