文献速递神经MR

加速液体与白质抑制成像准确诊断多发性硬化皮层及幕下病灶

Accurate Diagnosis of Cortical and Infratentorial Lesions in Multiple Sclerosis Using Accelerated Fluid and White Matter Suppression Imaging.
PubMed 文献 · Invest Radiol · 2022-11-10

前瞻性3T扫描回顾性分析42例多发性硬化患者,比较CS-FLAWS与PSIR联合3D DIR对皮层及幕下病灶的分类诊断效能。CS-FLAWS检出的皮层病灶(263 vs 251)和幕下病灶(123 vs 109)数量与PSIR无显著差异,但假阴性更少(皮层1 vs 13,幕下1 vs 15,P<0.01),诊断置信度高,全脑扫描仅需5分15秒。

要点

  • CS-FLAWS在3T下对MS皮层和幕下病灶的检出与PSIR相当,且假阴性更少。
  • CS-FLAWS全脑扫描时间约5分15秒,适合临床常规MS全脑评估。
  • 联合3D DIR可提高皮层和幕下病灶分类的可靠性。

关键影像表现/征象

  • CS-FLAWS检出皮层病灶263个,PSIR检出251个(P=0.74)。
  • CS-FLAWS检出幕下病灶123个,PSIR检出109个(P=0.63)。
  • CS-FLAWS皮层病灶假阴性1个,PSIR假阴性13个(P<0.01)。
  • CS-FLAWS幕下病灶假阴性1个,PSIR假阴性15个(P<0.01)。
  • 两种序列均无假阳性发现,各对比诊断置信度均高。

临床应用与阅片要点

  • 日常阅片可采用3D CS-FLAWS联合3D DIR评估MS皮层及幕下病灶,减少漏诊。
  • CS-FLAWS扫描时间约5分15秒,适合纳入MS全脑常规协议。
  • 注意皮层病灶与近皮层病灶的区分,CS-FLAWS假阴性少有助于分类。

局限性

  • 回顾性分析设计。
  • 单中心研究,样本量42例。
  • 仅纳入3T扫描数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The precise location of multiple sclerosis (MS) cortical lesions can be very challenging at 3 T, yet distinguishing them from subcortical lesions is essential for the diagnosis and prognosis of the disease. Compressed sensing-accelerated fluid and white matter suppression imaging (CS-FLAWS) is a new magnetic resonance imaging sequence derived from magnetization-prepared 2 rapid acquisition gradient echo with promising features for the detection and classification of MS lesions. The objective of this study was to compare the diagnostic performances of CS-FLAWS (evaluated imaging) and phase sensitive inversion recovery (PSIR; reference imaging) for classification of cortical lesions (primary objective) and infratentorial lesions (secondary objective) in MS, in combination with 3-dimensional (3D) double inversion recovery (DIR).

MATERIALS AND METHODS: Prospective 3 T scans (MS first diagnosis or follow-up) acquired between March and August 2021 were retrospectively analyzed. All underwent 3D CS-FLAWS, axial 2D PSIR, and 3D DIR. Double-blinded reading sessions exclusively in axial plane and final consensual reading were performed to assess the number of cortical and infratentorial lesions. Wilcoxon test was used to compare the 2 imaging datasets (FLAWS + DIR and PSIR + DIR), and intraobserver and interobserver agreement was assessed using the intraclass correlation coefficient.

RESULTS: Forty-two patients were analyzed (38 with relapsing-remitting MS, 29 women, 42.7 ± 12.6 years old). Compressed sensing-accelerated FLAWS allowed the identification of 263 cortical lesions versus 251 with PSIR ( P = 0.74) and 123 infratentorial lesions versus 109 with PSIR ( P = 0.63), corresponding to a nonsignificant difference between the 2 sequences. Compressed sensing-accelerated FLAWS exhibited fewer false-negative findings than PSIR either for cortical lesions (1 vs 13; P < 0.01) or infratentorial lesions (1 vs 15; P < 0.01). No false-positive findings were found with any of the 2 sequences. Diagnostic confidence was high for each contrast.

CONCLUSION: Three-dimensional CS-FLAWS is as accurate as 2D PSIR imaging for classification of cortical and infratentorial MS lesions, with fewer false-negative findings, opening the way to a reliable full brain MS exploration in a clinically acceptable duration (5 minutes 15 seconds).

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Martin, Emorine, Megdiche, et al. Accurate Diagnosis of Cortical and Infratentorial Lesions in Multiple Sclerosis Using Accelerated Fluid and White Matter Suppression Imaging. Invest Radiol. 2022. PMID: 36730698. doi:10.1097/RLI.0000000000000939

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。