文献速递骨肌神经CT

基于XGBoost的双能CT多参数鉴别脊柱多发性骨髓瘤与椎体溶骨性转移

XGBoost-based multiparameters from dual-energy computed tomography for the differentiation of multiple myeloma of the spine from vertebral osteolytic metastases.
PubMed 文献 · Eur Radiol · 2023-01-31

回顾性纳入28例脊柱多发性骨髓瘤(83个病灶)和23例椎体溶骨性转移(54个病灶),采用双能CT多参数结合XGBoost构建预测模型。MM的mpDECT参数均显著低于VOM,虚拟去钙(VNCa)在单变量分析中AUC最高(训练组0.81,测试组0.87)。XGBoost模型在测试组AUC达0.97,敏感度80%、特异度95%、准确率88%,优于VNCa(p<0.05)。

要点

  • 双能CT多参数(VNCa、能谱曲线斜率、有效原子序数等)可辅助鉴别脊柱MM与溶骨性转移。
  • VNCa是单参数中鉴别效能最高的指标,测试组AUC为0.87。
  • XGBoost多参数模型测试组AUC 0.97,敏感度80%、特异度95%、准确率88%。

关键影像表现/征象

  • 多发性骨髓瘤的双能CT多参数值均显著低于椎体溶骨性转移(p<0.05)。
  • VNCa在单变量分析中鉴别效能最高,训练组AUC 0.81,测试组AUC 0.87。

诊断标准与关键数值

  • XGBoost模型基于Boruta筛选的6个DECT参数构建,训练组AUC 1.0,测试组AUC 0.97。
  • 测试组敏感度80%、特异度95%、准确率88%,优于VNCa(p<0.05)。

临床应用与阅片要点

  • 日常阅片遇脊柱溶骨性病变时,可参考双能CT多参数(尤其VNCa)辅助鉴别MM与转移瘤。
  • XGBoost模型需依托双能CT多参数后处理,单参数VNCa可作为快速筛查指标。

局限性

  • 回顾性研究,样本量较小(MM 28例,VOM 23例),来自单中心。
  • 模型区分MM与VOM的敏感度80%,存在一定漏诊可能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the performance of extreme gradient boosting (XGBoost) combined with multiparameters from dual-energy computed tomography (mpDECT) to differentiate between multiple myeloma (MM) of the spine and vertebral osteolytic metastases (VOM).

METHODS: For this retrospective study, 28 patients (83 lesions) with MM of the spine and 23 patients (54 lesions) with VOM who underwent DECT were included. The mpDECT for each lesion, including normalized effective atomic number, slope of the spectral Hounsfield unit curve, CT attenuation, and virtual noncalcium (VNCa), was obtained. Boruta was used to select the key parameters, and then subsequently merged with XGBoost to yield a prediction model. The lesions were divided into the training and testing group in a 3:1 ratio. The highest performance of the univariate analysis was compared with XGBoost using the Delong test.

RESULTS: The mpDECT of MM was significantly lower than that of VOM (all p < 0.05). In univariate analysis, VNCa had the highest area under the receiver operating characteristic curve (AUC) in the training group (0.81) and testing group (0.87). Based on Boruta, 6 parameters of DECT were selected for XGBoost model construction. The XGBoost model achieved an excellent and stable diagnostic performance, as shown in the training group (AUC of 1.0) and testing group (AUC of 0.97), with a sensitivity of 80%, a specificity of 95%, and an accuracy of 88%, which was superior to VNCa (p < 0.05).

CONCLUSIONS: XGBoost combined with mpDECT yielded promising performance in differentiating between MM of the spine and VOM.

KEY POINTS: • The multiparameters obtained from dual-energy CT of multiple myeloma differed significantly from those of vertebral osteolytic metastases. • The virtual noncalcium offered the highest AUC in the univariate analysis to distinguish multiple myeloma from vertebral osteolytic metastases. • Extreme gradient boosting combined with multiparameters from dual-energy CT had a promising performance to distinguish multiple myeloma from vertebral osteolytic metastases.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Shi, Huang, Xu, et al. XGBoost-based multiparameters from dual-energy computed tomography for the differentiation of multiple myeloma of the spine from vertebral osteolytic metastases. Eur Radiol. 2023. PMID: 36719494. doi:10.1007/s00330-023-09404-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。