文献速递腹部MR

单次屏气三维磁共振弹性成像评估肥胖患者肝纤维化与炎症

Single Breath-Hold 3-Dimensional Magnetic Resonance Elastography Depicts Liver Fibrosis and Inflammation in Obese Patients.
PubMed 文献 · Invest Radiol · 2023-01-21

前瞻性纳入10名健康志愿者和10名疑似非酒精性脂肪性肝病的肥胖患者,比较单次屏气与多次屏气三维MRE序列,并在患者中与Ishak评分对照。单次屏气序列与多次屏气序列一致性良好,且剪切波速度与纤维化分级、损耗模量与炎症分级显著相关。单次屏气三维MRE或可有效评估肥胖患者的肝纤维化和炎症。

要点

  • 单次屏气3D MRE与多次屏气序列在|G*|、Cs、G"上差异小于6.5%,一致性良好。
  • 在肥胖患者中,Cs与Ishak纤维化分级显著相关(ρ=0.95,P<0.001)。
  • G"与Ishak炎症分级显著相关(ρ=0.84,P=0.002)。

诊断标准与关键数值

  • 单次屏气与多次屏气3D MRE序列在|G*|、Cs和G"的Bland-Altman分析差异均低于6.5%。
  • 参与者中Cs与Ishak纤维化分级显著相关(ρ=0.95,P<0.001)。
  • 参与者中G"与Ishak炎症分级显著相关(ρ=0.84,P=0.002)。

临床应用与阅片要点

  • 单次屏气3D MRE可减少屏气次数,提高肥胖患者检查耐受性和临床可接受性。
  • 测量参数Cs和G"可分别用于评估肝纤维化和炎症,辅助无创肝病评估。
  • 需注意本研究样本量小,相关阈值和诊断效能尚未建立。

局限性

  • 样本量小(对照组和参与者各10例),结论需更大样本验证。
  • 单中心前瞻性研究,可能存在选择偏倚。
  • 未报告诊断阈值、敏感度、特异度或AUC。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Three-dimensional (3D) magnetic resonance elastography (MRE) measures liver fibrosis and inflammation but requires several breath-holds that hamper clinical acceptance. The aim of this study was to evaluate the technical and clinical feasibility of a single breath-hold 3D MRE sequence as a means of measuring liver fibrosis and inflammation in obese patients.

METHODS: From November 2020 to December 2021, subjects were prospectively enrolled and divided into 2 groups. Group 1 included healthy volunteers (n = 10) who served as controls to compare the single breath-hold 3D MRE sequence with a multiple-breath-hold 3D MRE sequence. Group 2 included liver patients (n = 10) who served as participants to evaluate the clinical feasibility of the single breath-hold 3D MRE sequence in measuring liver fibrosis and inflammation. Controls and participants were scanned at 60 Hz mechanical excitation with the single breath-hold 3D MRE sequence to retrieve the magnitude of the complex-valued shear modulus (|G*| [kPa]), the shear wave speed (Cs [m/s]), and the loss modulus (G" [kPa]). The controls were also scanned with a multiple-breath-hold 3D MRE sequence for comparison, and the participants had histopathology (Ishak scores) for correlation with Cs and G".

RESULTS: For the 10 controls, 5 were female, and the mean age and body mass index were 33.1 ± 9.5 years and 23.0 ± 2.1 kg/m 2 , respectively. For the 10 participants, 8 were female, and the mean age and body mass index were 45.1 ± 16.5 years and 33.1 ± 4.0 kg/m 2 (obese range), respectively. All participants were suspected of having nonalcoholic fatty liver disease. Bland-Altman analysis of the comparison in controls shows there are nonsignificant differences in |G*|, Cs, and G" below 6.5%, suggesting good consensus between the 2 sequences. For the participants, Cs and G" correlated significantly with Ishak fibrosis and inflammation grades, respectively ( ρ = 0.95, P < 0.001, and ρ = 0.84, P = 0.002).

CONCLUSION: The single breath-hold 3D MRE sequence may be effective in measuring liver fibrosis and inflammation in obese patients.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Darwish, Gharib, Jeljeli, et al. Single Breath-Hold 3-Dimensional Magnetic Resonance Elastography Depicts Liver Fibrosis and Inflammation in Obese Patients. Invest Radiol. 2023. PMID: 36719974. doi:10.1097/RLI.0000000000000952

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。