基于胸部低剂量CT的自动分割与影像组学纹理分析用于骨质疏松筛查
本研究开发了一种结合机器学习分割与影像组学纹理分析的工具,用于胸部低剂量CT的骨密度筛查。共分析197例接受LDCT及双能X线吸收检测的患者,自动分割胸椎体的Sorenson-Dice系数为0.87±0.01。两级分类器检测骨密度异常的AUC为0.96±0.01,区分骨质疏松的AUC为0.98±0.01,总体测试准确率0.90±0.05。
要点
- 自动分割胸椎体Dice系数0.87,可用于后续纹理分析。
- 两级分类器检测骨密度异常AUC 0.96,区分骨质疏松AUC 0.98。
- 该方法无需定量CT或体模,可在肺癌筛查中机会性筛查骨质疏松。
局限性
- 单中心回顾性研究,样本量197例。
- 未报告外部验证结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study developed a diagnostic tool combining machine learning (ML) segmentation and radiomic texture analysis (RTA) for bone density screening using chest low-dose computed tomography (LDCT).
METHODS: A total of 197 patients who underwent LDCT followed by dual-energy X-ray absorptiometry were analyzed. First, an autosegmentation model was trained using LDCT to delineate the thoracic vertebral body (VB). Second, a two-level classifier was developed using radiomic features extracted from VBs for the hierarchical pairwise classification of each patient's bone status. All the patients were initially classified as either normal or abnormal, and all patients with abnormal bone density were then subdivided into an osteopenia group and an osteoporosis group. The performance of the classifier was evaluated through fivefold cross-validation.
RESULTS: The model for automated VB segmentation achieved a Sorenson-Dice coefficient of 0.87 ± 0.01. Furthermore, the area under the receiver operating characteristic curve scores for the two-level classifier were 0.96 ± 0.01 for detecting abnormal bone density (accuracy = 0.91 ± 0.02; sensitivity = 0.93 ± 0.03; specificity = 0.89 ± 0.03) and 0.98 ± 0.01 for distinguishing osteoporosis (accuracy = 0.94 ± 0.02; sensitivity = 0.95 ± 0.03; specificity = 0.93 ± 0.03). The testing prediction accuracy levels for the first- and second-level classifiers were 0.92 ± 0.04 and 0.94 ± 0.05, respectively. The overall testing prediction accuracy of our method was 0.90 ± 0.05.
CONCLUSION: The combination of ML segmentation and RTA for automated bone density prediction based on LDCT scans is a feasible approach that could be valuable for osteoporosis screening during lung cancer screening.
KEY POINTS: • This study developed an automatic diagnostic tool combining machine learning-based segmentation and radiomic texture analysis for bone density screening using chest low-dose computed tomography. • The developed method enables opportunistic screening without quantitative computed tomography or a dedicated phantom. • The developed method could be integrated into the current clinical workflow and used as an adjunct for opportunistic screening or for patients who are ineligible for screening with dual-energy X-ray absorptiometry.
引用
- Chen, Li, Kuo, et al. Automatic segmentation and radiomic texture analysis for osteoporosis screening using chest low-dose computed tomography. Eur Radiol. 2023. PMID: 36719495. doi:10.1007/s00330-023-09421-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。