文献速递神经介入CT

双轴「蝴蝶」轨迹锥形束CT改善神经介入术后脑软组织图像质量

Image quality improvements for brain soft tissue in neuro-endovascular treatments: A novel dual-axis "butterfly" trajectory for optimized Cone-Beam CT.
PubMed 文献 · Eur J Radiol · 2023-01-24

结果显示蝴蝶CBCT在幕上、幕下伪影评分及脑实质对比度、皮髓质交界分辨力上均显著优于传统CBCT,额叶和枕叶白质/灰质ROI比值显著更高,颞叶无显著差异。

要点

  • 双轴蝴蝶CBCT可显著减少幕上、幕下伪影,有利于神经介入术后并发症评估。
  • 蝴蝶CBCT改善脑实质与脑脊液间隙对比度及白质/灰质分辨力。
  • 额叶、枕叶白质/灰质ROI比值提高,颞叶未见显著改善。

关键影像表现/征象

  • 蝴蝶CBCT在幕上及幕下伪影评估中评分显著更低(图像质量更好)。
  • 蝴蝶CBCT在大脑半球所有区域的对比度和皮髓质交界分辨力评分均显著更优。
  • 额叶和枕叶白质/灰质ROI比值在蝴蝶CBCT中显著更高,颞叶无显著差异。

临床应用与阅片要点

  • 神经介入术后需评估脑实质并发症时,可优先选用双轴蝴蝶CBCT以减少伪影干扰。
  • 阅片时注意颞叶区域白质/灰质分辨力改善不明显,仍需结合其他序列或CT。

局限性

  • 仅评估图像质量,未涉及诊断准确性或临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Cone-beam computed tomography (CBCT) is useful in the diagnosis of complications after neuro-endovascular treatment. However, the image quality of conventional CBCT is inferior to that of conventional CT. To solve this problem, a dual-axis butterfly CBCT available with an angiography suite has been developed. This study aimed to evaluate the image quality of this dual-axis butterfly CBCT compared to the conventional CBCT in the same patient.

METHOD: We prospectively included patients who underwent scheduled neuro-endovascular treatment and performed conventional CBCT and novel dual-axis butterfly CBCT as a postoperative examination. We evaluated artifacts, brain contrast, and cortico-medullary junctions on a scoring system using a 5-point scale in which lower scores indicate better image quality. In addition, the white matter/gray matter ratio was calculated in selected brain lobe regions.

RESULTS: Forty-seven cases (94 paired images) were enrolled. The novel dual-axis butterfly CBCT had significantly fewer supratentorial and infratentorial artifacts in the artifact evaluation. Similarly, contrast and cortico-medullary junction discrimination in the cerebral hemispheres scored significantly better in the butterfly scan in all regions. The white matter/gray matter ROI ratio was significantly higher in the novel dual-axis butterfly CBCT in the frontal and occipital lobes but not in the temporal lobe.

CONCLUSIONS: Compared to conventional CBCT, the novel dual-axis butterfly CBCT showed supratentorial and infratentorial artifact reduction as well as improved contrast with the brain parenchyma and cerebrospinal fluid space and white matter/gray matter discrimination ability.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hosoo, Ito, Marushima, et al. Image quality improvements for brain soft tissue in neuro-endovascular treatments: A novel dual-axis "butterfly" trajectory for optimized Cone-Beam CT. Eur J Radiol. 2023. PMID: 36716548. doi:10.1016/j.ejrad.2023.110713

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。