文献速递腹部MR

无退变的胰腺实性假乳头状肿瘤能否通过影像诊断?与神经内分泌肿瘤及导管腺癌实性成分的比较研究

Can solid pseudopapillary neoplasm of the pancreas without degeneration be diagnosed with imaging? a comparison study of the solid component of solid pseudopapillary neoplasm, neuroendocrine neoplasm, and ductal adenocarcinoma.
PubMed 文献 · Abdom Radiol (NY) · 2023-01-28

回顾性比较23例SPN、23例PNEN和46例PDAC的实性成分MR表现,定性评估T2WI和MRCP有显著差异。SPN实性成分在FSE T2WI上信号强度比(SIR)均值1.99-2.01,显著高于PNEN(1.30-1.31)和PDAC(1.26-1.28)。T2WI呈高信号(评分4-5或SIR≥1.5)诊断SPN的敏感度78.9-100.0%、特异度63.8-79.7%;显著高信号(评分5、SIR≥2.0或MRCP可见)或盐胡椒征的敏感度36.8-68.4%、特异度85.5-98.6%。

要点

  • FSE T2WI是鉴别实性SPN的关键序列,实性成分信号强度比显著高于PNEN和PDAC。
  • T2WI信号高于肾皮质、超过胰腺实质2倍、MRCP可见或盐胡椒征提示SPN。
  • T2WI高信号诊断SPN敏感度高但特异度中等,显著高信号或盐胡椒征特异度高。
英文原文(摘要)· 点击展开

PURPOSE: To investigate the MR findings of the solid components within pancreatic solid pseudopapillary neoplasms (SPNs) to characterize solid SPN without degeneration.

METHODS: After case matching, 23 patients with SPNs, 23 with pancreatic neuroendocrine neoplasms (PNENs), and 46 pancreatic ductal adenocarcinomas (PDACs) were included in this retrospective comparative study. The MR findings of the solid components within the pancreatic tumors were assessed qualitatively and semi-quantitatively.

RESULTS: In the qualitative assessment, significant differences were noted in T2-weighted imaging and MR cholangiopancreatography (MRCP). SPNs with a score of 4-5 (iso- to hyper-intense compared with the renal cortex) were observed in 18/19 (94.7%) by reader 1 and 15/19 (78.9%) by reader 2 (score 5, 52.6% and 47.4%) on fast spin-echo (FSE) T2-weighted imaging. On MRCP, the two readers identified 12 (63.2%) and 8 (42.1%) SPNs, respectively. The semi-quantitative signal-intensity ratio (SIR, signal intensity of tumor/signal intensity of the pancreatic parenchyma) of SPNs on FSE T2-weighted imaging was significantly higher (mean, 1.99-2.01) than that of PNENs (1.30-1.31) or PDACs (1.26-1.28). The sensitivity/specificity of 'hyper' on T2-weighted imaging (qualitative score of 4-5, or SIR of ≥ 1.5) were 78.9-100.0%/63.8-79.7%. The sensitivity/specificity of 'remarkably hyper' (score of 5, SIR of ≥ 2.0, or visible on MRCP) or salt-and-pepper pattern were 36.8-68.4%/85.5-98.6%.

CONCLUSION: T2-weighted imaging may be the key sequence for solid SPN. Solid tumors with hyper-intensity on T2-weighted imaging (especially, more hyper-intense than the renal cortex, more than twice the signal of the pancreatic parenchyma, depicted on MRCP, or salt-and-pepper appearance) may be suspected to be SPNs.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Toshima, Inoue, Kozaka, et al. Can solid pseudopapillary neoplasm of the pancreas without degeneration be diagnosed with imaging? a comparison study of the solid component of solid pseudopapillary neoplasm, neuroendocrine neoplasm, and ductal adenocarcinoma. Abdom Radiol (NY). 2023. PMID: 36708377. doi:10.1007/s00261-023-03814-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。