文献速递神经MR

多发性硬化脊髓腔室全自动分割可靠方法

Fully Automatic Method for Reliable Spinal Cord Compartment Segmentation in Multiple Sclerosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-01-26

本研究提出全自动脊髓腔室分割方法SCORE,在24例MS患者和24例健康对照的3T磁共振数据上训练神经网络,并与人工分割比较。SCORE在灰质和白质分割上重现性高、精度优,且MS患者白质总面积和前角面积降低,提示可作为MS生物标志物。

要点

  • SCORE可全自动分割脊髓灰质、白质、前角、后角、灰质连合及MS病灶
  • SCORE重现性优于人工分割,灰质和白质Dice系数分别≥0.84和≥0.92
  • MS患者白质总面积和前角面积降低,可能作为影像生物标志物

关键影像表现/征象

  • SCORE分割的脊髓灰质和白质平均相对标准差分别≤3.50%和≤1.47%,重现性高
  • SCORE与手动分割相比,健康对照和MS患者的灰质Dice系数≥0.84、白质≥0.92
  • MS患者白质总面积降低(P < .05),前角总面积降低(P < .01)

诊断标准与关键数值

  • SCORE重现性以组内和组间平均相对标准差评估,灰质≤3.50%、白质≤1.47%
  • SCORE准确性以Dice相似系数评估,灰质≥0.84、白质≥0.92
  • MS患者白质总面积降低P < .05,前角总面积降低P < .01

临床应用与阅片要点

  • 可自动量化脊髓灰质、白质及亚区面积,辅助MS脊髓受累评估
  • SCORE重现性优于人工分割,适合纵向随访和定量报告
  • 注意当前方法基于颈髓3T磁共振数据,推广需验证

局限性

  • 样本量较小(24例MS和24例对照),单中心研究
  • 仅评估颈髓,未涉及胸髓或其他序列

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Fully automatic quantification methods of spinal cord compartments are needed to study pathologic changes of the spinal cord GM and WM in MS in vivo. We propose a novel method for automatic spinal cord compartment segmentation (SCORE) in patients with MS.

MATERIALS AND METHODS: The cervical spinal cords of 24 patients with MS and 24 sex- and age-matched healthy controls were scanned on a 3T MR imaging system, including an averaged magnetization inversion recovery acquisition sequence. Three experienced raters manually segmented the spinal cord GM and WM, anterior and posterior horns, gray commissure, and MS lesions. Subsequently, manual segmentations were used to train neural segmentation networks of spinal cord compartments with multidimensional gated recurrent units in a 3-fold cross-validation fashion. Total intracranial volumes were quantified using FreeSurfer.

RESULTS: The intra- and intersession reproducibility of SCORE was high in all spinal cord compartments (eg, mean relative SD of GM and WM: ≤ 3.50% and ≤1.47%, respectively) and was better than manual segmentations (all P < .001). The accuracy of SCORE compared with manual segmentations was excellent, both in healthy controls and in patients with MS (Dice similarity coefficients of GM and WM: ≥ 0.84 and ≥0.92, respectively). Patients with MS had lower total WM areas (P < .05), and total anterior horn areas (P < .01 respectively), as measured with SCORE.

CONCLUSIONS: We demonstrate a novel, reliable quantification method for spinal cord tissue segmentation in healthy controls and patients with MS and other neurologic disorders affecting the spinal cord. Patients with MS have reduced areas in specific spinal cord tissue compartments, which may be used as MS biomarkers.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Tsagkas, Horvath-Huck, Haas, et al. Fully Automatic Method for Reliable Spinal Cord Compartment Segmentation in Multiple Sclerosis. AJNR Am J Neuroradiol. 2023. PMID: 36702504. doi:10.3174/ajnr.A7756

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。