MRI定量绝经后骨质疏松的骨皮质孔隙率、矿化及形态结构
结果显示OP组孔隙水及总水升高、骨皮质厚度及磷密度降低,且MRI指标与骨密度相关。
要点
- OP组骨皮质孔隙水及总水密度升高,骨皮质厚度及31P密度降低。
- 孔隙水/总水与DXA及pQCT骨密度负相关,骨皮质厚度及31P密度正相关。
- 固体MRI可无创评估骨皮质孔隙率、形态及矿化,辅助骨质疏松评估。
关键影像表现/征象
- OP组胫骨中段骨皮质孔隙水密度为11.6 mol/L,高于非OP组的9.5 mol/L(P = .007)。
- OP组总水密度为21.2 mol/L,高于非OP组的19.7 mol/L(P = .03)。
- OP组骨皮质厚度为4.8 mm,低于非OP组的5.6 mm(P < .001)。
- OP组31P密度为6.4 mol/L,低于非OP组的7.5 mol/L(P = .01)。
- 结合水及31P与结合水浓度比在两组间无差异证据。
诊断标准与关键数值
- 骨质疏松症定义:任何DXA T值≤-2.5。
- 孔隙水及总水密度与DXA和pQCT骨密度负相关(P < .001)。
- 骨皮质厚度及31P密度与DXA和pQCT骨密度正相关(P = .01)。
- 结合水、31P密度及31P/结合水浓度比与DXA正相关(P < .05),但与pQCT无关联。
局限性
- 仅评估胫骨中段,未覆盖其他骨骼部位。
- 横断面设计,无法推断因果关系或纵向变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Preclinical studies have suggested that solid-state MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are useful measures of bone health. Purpose To explore whether MRI markers of cortical bone porosity, morphologic structure, mineralization, and osteoid density are affected in postmenopausal osteoporosis (OP) and to examine associations between MRI markers and bone mineral density (BMD) in postmenopausal women. Materials and Methods In this single-center study, postmenopausal women were prospectively recruited from January 2019 to October 2020 into two groups: participants with OP who had not undergone treatment, defined as having any dual-energy x-ray absorptiometry (DXA) T-score of -2.5 or less, and age-matched control participants without OP (hereafter, non-OP). Participants underwent MRI in the midtibia, along with DXA in the hip and spine, and peripheral quantitative CT in the midtibia. Specifically, MRI measures of cortical bone porosity (pore water and total water), osteoid density (bound water [BW]), morphologic structure (cortical bone thickness), and mineralization (phosphorous [P] density [31P] and 31P-to-BW concentration ratio) were quantified at 3.0 T. MRI measures were compared between OP and non-OP groups and correlations with BMD were assessed. Results Fifteen participants with OP (mean age, 63 years ± 5 [SD]) and 19 participants without OP (mean age, 65 years ± 6) were evaluated. The OP group had elevated pore water (11.6 mol/L vs 9.5 mol/L; P = .007) and total water densities (21.2 mol/L vs 19.7 mol/L; P = .03), and had lower cortical bone thickness (4.8 mm vs 5.6 mm; P < .001) and 31P density (6.4 mol/L vs 7.5 mol/L; P = .01) than the non-OP group, respectively, although there was no evidence of a difference in BW or 31P-to-BW concentration ratio. Pore and total water densities were inversely associated with DXA and peripheral quantitative CT BMD (P < .001), whereas cortical bone thickness and 31P density were positively associated with DXA and peripheral quantitative CT BMD (P = .01). BW, 31P density, and 31P-to-BW concentration ratio were positively associated with DXA (P < .05), but not with peripheral quantitative CT. Conclusion Solid-state MRI of cortical bone was able to help detect potential impairments in parameters reflecting porosity, morphologic structure, and mineralization in postmenopausal osteoporosis. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bae in this issue.
引用
- Jones, Lee, Cheng, et al. MRI Quantification of Cortical Bone Porosity, Mineralization, and Morphologic Structure in Postmenopausal Osteoporosis. Radiology. 2023. PMID: 36692396. doi:10.1148/radiol.221810
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。