自由呼吸下基于单次激发多重叠回波采集与深度学习重建的腹部T2即时成像
本研究开发了一种无需屏气或呼吸门控的实时腹部T2定量方法,采用单次激发多重叠回波分离(MOLED)序列结合深度学习重建,通过基于Bloch模拟的合成数据生成流程克服训练数据不足。仿真和体内实验显示高质量T2成像,在33个局灶性肝脏病变中,良性病变T2均值为141.1±50.0 ms,恶性为63.3±16.0 ms,重测变异系数在肝脏、肾脏、胆囊、脾脏和骨骼肌分别为2.9%、1.2%、0.9%、3.1%和1.8%。
要点
- 自由呼吸腹部T2定量成像可在约100 ms内完成,无需屏气或呼吸门控。
- 深度学习重建结合合成数据生成可解决腹部训练数据不足的问题。
- 可实时捕捉对比剂注射前后腹部器官T2值变化,肝良性病变T2均值141.1 ms,恶性63.3 ms。
关键影像表现/征象
- 仿真和活体实验显示本方法可提供高质量T2定量成像。
诊断标准与关键数值
- 数字体模实验:平均归一化均方误差(NMSE)为0.0178,线性回归R²为0.9751。
- 体模实验:预测T2与参考T2的Pearson相关系数为0.9996。
- 患者组共检出33个局灶性肝脏病变:良性病变T2均值和标准差为141.1 ± 50.0 ms,恶性病变为63.3 ± 16.0 ms。
- 重测实验变异系数:肝脏2.9%、肾脏1.2%、胆囊0.9%、脾脏3.1%、骨骼肌1.8%。
临床应用与阅片要点
- 可用于自由呼吸患者腹部T2定量,无需屏气或呼吸门控,约100 ms内完成采集。
- 可实时捕捉对比剂注射前后腹部器官T2值变化,辅助病变定性。
- 肝局灶性病变T2值有助于鉴别良恶性(良性141.1 ms,恶性63.3 ms)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop a real-time abdominal T2 mapping method without requiring breath-holding or respiratory-gating.
METHODS: The single-shot multiple overlapping-echo detachment (MOLED) pulse sequence was employed to achieve free-breathing T2 mapping of the abdomen. Deep learning was used to untangle the non-linear relationship between the MOLED signal and T2 mapping. A synthetic data generation flow based on Bloch simulation, modality synthesis, and randomization was proposed to overcome the inadequacy of real-world training set.
RESULTS: The results from simulation and in vivo experiments demonstrated that our method could deliver high-quality T2 mapping. The average NMSE and R2 values of linear regression in the digital phantom experiments were 0.0178 and 0.9751. Pearson's correlation coefficient between our predicted T2 and reference T2 in the phantom experiments was 0.9996. In the measurements for the patients, real-time capture of the T2 value changes of various abdominal organs before and after contrast agent injection was realized. A total of 33 focal liver lesions were detected in the group, and the mean and standard deviation of T2 values were 141.1 ± 50.0 ms for benign and 63.3 ± 16.0 ms for malignant lesions. The coefficients of variance in a test-retest experiment were 2.9%, 1.2%, 0.9%, 3.1%, and 1.8% for the liver, kidney, gallbladder, spleen, and skeletal muscle, respectively.
CONCLUSIONS: Free-breathing abdominal T2 mapping is achieved in about 100 ms on a clinical MRI scanner. The work paved the way for the development of real-time dynamic T2 mapping in the abdomen.
KEY POINTS: • MOLED achieves free-breathing abdominal T2 mapping in about 100 ms, enabling real-time capture of T2 value changes due to CA injection in abdominal organs. • Synthetic data generation flow mitigates the issue of lack of sizable abdominal training datasets.
引用
- Lin, Dai, Yang, et al. Free-breathing and instantaneous abdominal T2 mapping via single-shot multiple overlapping-echo acquisition and deep learning reconstruction. Eur Radiol. 2023. PMID: 36692597. doi:10.1007/s00330-023-09417-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。