定量MRI鉴别膀胱副神经节瘤与膀胱平滑肌瘤
回顾性纳入2014-2021年经手术病理证实的11例膀胱副神经节瘤和14例膀胱平滑肌瘤患者,均行3.0T多参数MRI。结果显示T1WI信号强度比、ADC值及E-rate在两组间差异有统计学意义,其中T1WI信号强度比和ADC值鉴别诊断效能较高。
要点
- T1WI信号强度比鉴别膀胱副神经节瘤与平滑肌瘤的AUC达1.000。
- ADC值鉴别两者AUC为0.907,诊断效能亦较高。
- E-rate鉴别效能相对较低,AUC为0.714。
核心结论
- 定量MRI参数T1WI信号强度比和ADC值可有效鉴别膀胱副神经节瘤与膀胱平滑肌瘤。
- T1WI信号强度比和ADC值的诊断效能均显著高于E-rate。
研究设计与样本
- 回顾性研究,纳入2014至2021年经手术病理证实的11例膀胱副神经节瘤和14例膀胱平滑肌瘤患者。
- 所有患者均行3.0T MR多参数扫描。
- 定量参数包括肿瘤实性部分与梨状肌的T1WI信号强度比、ADC值及肿瘤实性部分的E-rate。
- 采用独立样本t检验或Mann-Whitney U检验比较两组参数,ROC曲线及DeLong检验评估诊断效能。
关键影像表现/征象
- 膀胱副神经节瘤与膀胱平滑肌瘤在T1WI信号强度比(P < 0.001)、ADC值(P = 0.002)和E-rate(P = 0.040)上差异有统计学意义。
诊断标准与关键数值
- T1WI信号强度比鉴别平滑肌瘤的截断值为1.241,AUC为1.000(95%CI 0.858-1.000)。
- ADC值鉴别诊断的截断值为0.979 × 10-3mm2/s,AUC为0.907(95%CI 0.717-0.987)。
- E-rate的截断值为98.7%,AUC为0.714(95%CI 0.495-0.878)。
- T1WI信号强度比与ADC值的AUC均显著高于E-rate(P = 0.015和P = 0.034)。
临床应用与阅片要点
- 阅片时可测量肿瘤实性部分与梨状肌的T1WI信号强度比,以1.241为截断值辅助鉴别。
- ADC值可作为鉴别膀胱副神经节瘤与平滑肌瘤的定量指标,截断值0.979 × 10-3mm2/s。
局限性
- 回顾性研究,样本量较小(副神经节瘤11例,平滑肌瘤14例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the feasibility of quantitative MRI in the differentiation of bladder paraganglioma from bladder leiomyoma.
METHODS: From 2014 to 2021, 11 patients with bladder paraganglioma and 14 patients with bladder leiomyoma confirmed by surgical pathology were retrospectively collected. All patients underwent multiparametric scanning with a 3.0 T MR system. Quantitative parameters including the SI-ratio on T1WI between the solid component of tumours and piriformis, ADC value and E-rate of the solid component of tumours were assessed. Independent sample t test or Mann-Whitney U test was used to compare these parameters between the two groups. The diagnostic efficiency of the parameters was examined using ROC curve analysis and the DeLong test.
RESULTS: There were significant differences in SI-ratio on T1WI (P < 0.001), ADC value (P = 0.002) and the E-rate (P = 0.040) between the paraganglioma group and the leiomyoma group. The cutoff value of SI-ratio on 3 leiomyoma was 1.241, and the AUC was 1.000 (0.858-1.000). The cutoff value of the ADC value was 0.979 × 10-3mm2/s, and the AUC was 0.907 (0.717-0.987). The cutoff value of E-rate was 98.7%, and the AUC was 0.714 (0.495-0.878). The AUCs of the SI-ratio on T1WI and ADC value were significantly higher than the E-rate AUC (P = 0.015 and 0.034, respectively).
CONCLUSION: Quantitative MRI can effectively distinguish bladder paraganglioma from bladder leiomyoma with the SI-ratio on T1WI or ADC value.
引用
- Hu, Wang, Sun, et al. Quantitative MRI in distinguishing bladder paraganglioma from bladder leiomyoma. Abdom Radiol (NY). 2023. PMID: 36690715. doi:10.1007/s00261-023-03812-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。