高分辨率超声表征癌症组织局部散射
本研究旨在比较H-scan超声图像局部强度与细胞水平组织学测量。将人乳腺癌细胞植入5只雌性小鼠,肿瘤生长约4周后,用15 MHz中心频率超声系统进行活体成像,并与组织学切片空间对齐。结果显示H-scan局部强度与癌细胞核大小显著相关(R2 > 0.27, p < 0.001),与核间距呈负相关(R2 > 0.17, p < 0.001)。
要点
- H-scan超声可无创评估癌细胞核大小和间距。
- 局部H-scan强度与核大小正相关,与核间距负相关。
- 该方法为组织 characterization 提供了高分辨率手段。
关键影像表现/征象
- H-scan超声图像局部强度与癌细胞核大小显著相关(R2 > 0.27, p < 0.001)。
- H-scan超声图像局部强度与核间距呈负相关(R2 > 0.17, p < 0.001)。
诊断标准与关键数值
- H-scan US通过并行卷积滤波器测量背向散射信号相对强度,并应用颜色编码显示。
- 局部H-scan强度与核大小相关性R2 > 0.27(p < 0.001),与核间距负相关R2 > 0.17(p < 0.001)。
临床应用与阅片要点
- H-scan超声可用于无创评估肿瘤组织细胞核特征,辅助组织 characterization。
局限性
- 样本量小(N=5),仅为动物模型研究,尚未在人体验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasound (US) has afforded an approach to tissue characterization for more than a decade. The challenge is to reveal hidden patterns in the US data that describe tissue function and pathology that cannot be seen in conventional US images. Our group has developed a high-resolution analysis technique for tissue characterization termed H-scan US, an imaging method used to interpret the relative size of acoustic scatterers. In the present study, the objective was to compare local H-scan US image intensity with registered histologic measurements made directly at the cellular level. Human breast cancer cells (MDA-MB 231, American Type Culture Collection, Manassas, VA, USA) were orthotopically implanted into female mice (N = 5). Tumors were allowed to grow for approximately 4 wk before the study started. In vivo imaging of tumor tissue was performed using a US system (Vantage 256, Verasonics Inc., Kirkland, WA, USA) equipped with a broadband capacitive micromachined ultrasonic linear array transducer (Kolo Medical, San Jose, CA, USA). A 15-MHz center frequency was used for plane wave imaging with five angles for spatial compounding. H-scan US image reconstruction involved use of parallel convolution filters to measure the relative strength of backscattered US signals. Color codes were applied to filter outputs to form the final H-scan US image display. For histologic processing, US imaging cross-sections were carefully marked on the tumor surface, and tumors were excised and sliced along the same plane. By use of optical microscopy, whole tumor tissue sections were scanned and digitized after nuclear staining. US images were interpolated to have the same number of pixels as the histology images and then spatially aligned. Each nucleus from the histologic sections was automatically segmented using custom MATLAB software (The MathWorks Inc., Natick, MA, USA). Nuclear size and spacing from the histology images were then compared with local H-scan US image features. Overall, local H-scan US image intensity exhibited a significant correlation with both cancer cell nuclear size (R2 > 0.27, p < 0.001) and the inverse relationship with nuclear spacing (R2 > 0.17, p < 0.001).
引用
- Khairalseed, Hoyt. High-Resolution Ultrasound Characterization of Local Scattering in Cancer Tissue. Ultrasound Med Biol. 2023. PMID: 36681609. doi:10.1016/j.ultrasmedbio.2022.11.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。