新辅助化疗期间乳腺多参数磁共振成像的分子标志
本研究整合383例乳腺癌患者治疗前基因表达谱与不同时间点MRI特征,分析功能肿瘤体积、最长径、球形度和对侧背景实质强化与分子通路及免疫浸润的关系;不同MRI特征反映不同肿瘤分子特征,可解释其临床意义,其中治疗后3周期球形度下降可预测新辅助化疗反应。
要点
- 功能肿瘤体积、最长径和球形度分别与增殖、信号传导和免疫相关通路显著相关。
- 对侧背景实质强化与基因表达改变无明显相关性。
- 治疗后3周期球形度下降与基线球形度及免疫特征负相关,可预测新辅助化疗反应。
核心结论
- 不同MRI特征捕捉不同肿瘤分子特征,可解释其对应的临床意义。
研究设计与样本
- 研究纳入383例患者进行MRI特征与分子信息整合分析,采用治疗前基因表达谱与不同治疗时间点MRI特征进行Spearman相关分析。
关键影像表现/征象
- 功能肿瘤体积、最长径和球形度测量分别与增殖、信号传导和免疫相关通路呈最显著正相关。
- 对侧背景实质强化未显示与基因表达改变状态有明显相关关系。
- 功能肿瘤体积、最长径和球形度均与部分免疫相关过程及免疫细胞浸润水平呈显著正相关或负相关。
诊断标准与关键数值
- 治疗后3周期球形度下降与基线球形度测量及免疫特征呈显著负相关,其下降状态可作为新辅助化疗反应预测指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To identify molecular basis of four parameters obtained from dynamic contrast-enhanced magnetic resonance imaging, including functional tumor volume (FTV), longest diameter (LD), sphericity, and contralateral background parenchymal enhancement (BPE).
MATERIAL AND METHODS: Pretreatment-available gene expression profiling and different treatment timepoints MRI features were integrated for Spearman correlation analysis. MRI feature-related genes were submitted to hypergeometric distribution-based gene functional enrichment analysis to identify related Kyoto Encyclopedia of Genes and Genomes annotation. Gene set variation analysis was utilized to assess the infiltration of distinct immune cells, which were used to determine relationships between immune phenotypes and medical imaging phenotypes. The clinical significance of MRI and relevant molecular features were analyzed to identify their prediction performance of neoadjuvant chemotherapy (NAC) and prognostic impact.
RESULTS: Three hundred and eighty-three patients were included for integrative analysis of MRI features and molecular information. FTV, LD, and sphericity measurements were most positively significantly correlated with proliferation-, signal transmission-, and immune-related pathways, respectively. However, BPE did not show marked correlation relationships with gene expression alteration status. FTV, LD and sphericity all showed significant positively or negatively correlated with some immune-related processes and immune cell infiltration levels. Sphericity decreased at 3 cycles after treatment initiation was also markedly negatively related to baseline sphericity measurements and immune signatures. Its decreased status could act as a predictor for prediction of response to NAC.
CONCLUSION: Different MRI features capture different tumor molecular characteristics that could explain their corresponding clinical significance.
引用
- Lin, Wan, Kang, et al. Molecular hallmarks of breast multiparametric magnetic resonance imaging during neoadjuvant chemotherapy. Radiol Med. 2023. PMID: 36680710. doi:10.1007/s11547-023-01595-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。