文献速递胸部介入CT

双层光谱CT碘密度值在CT引导肺穿刺活检中识别高肿瘤细胞比例区域的作用

Role of iodine density value on dual-energy CT for detection of high tumor cell proportion region in lung cancer during CT-guided transthoracic biopsy.
PubMed 文献 · Eur J Radiol · 2023-01-06

前瞻性研究纳入41例疑似肺癌患者,按局部碘密度值对疑似高/低肿瘤细胞比例区域分别穿刺,以20%为界评估82份标本;动脉期碘密度截断值0.59 mg/mL识别高肿瘤细胞比例区域特异度达97.10%,用于15例前瞻性验证准确率100%。

要点

  • 动脉期碘密度值0.59 mg/mL可用于穿刺前规划,识别肿瘤细胞比例≥20%的区域。
  • 光谱参数识别高肿瘤细胞比例区域的AUC均高于常规CT图像(均P<0.05)。
  • 该截断值在前瞻性验证15例中准确率达100%,支持用于指导穿刺路径设计。

核心结论

  • 光谱CT参数可用于识别肺癌中肿瘤细胞含量至少20%的区域,为经胸肺穿刺活检设计穿刺路径提供依据。
  • 动脉期碘密度截断值0.59 mg/mL识别高肿瘤细胞比例区域特异度97.10%,前瞻性验证准确率100%。

研究设计与样本

  • 前瞻性研究,先纳入41例疑似肺癌患者识别高肿瘤细胞比例区域并对82份标本行组织学评估。
  • 另纳入15例患者前瞻性验证最佳光谱参数截断值指导穿刺的准确性。
  • 采用双层光谱探测器CT(SDCT),参考标准为穿刺标本肿瘤细胞比例以20%为阈值分类。

诊断标准与关键数值

  • 以肿瘤细胞比例≥20%定义为高肿瘤细胞比例区域(HTPR),<20%为低肿瘤细胞比例区域(LTPR)。
  • 动脉期碘密度(IoD)识别HTPR的截断值为0.59 mg/mL,特异度97.10%。
  • 各光谱参数识别HTPR的AUC均高于常规CT(CTconventional),差异均有统计学意义(均P<0.05)。
  • 该截断值用于15例前瞻性验证,准确率为100%。

临床应用与阅片要点

  • 穿刺前可参考动脉期碘密度值≥0.59 mg/mL的区域设计穿刺路径,以提高获取高肿瘤细胞比例标本的概率。
  • 光谱参数识别HTPR的AUC均优于常规CT图像,提示碘密度图可作为常规CT的补充。
  • 该截断值来自单中心小样本前瞻性研究,用于日常规划时需结合术者经验与病灶位置综合判断。

局限性

  • 识别队列样本量41例、验证队列15例,样本量较小。
  • 单中心前瞻性研究,外部推广性需进一步多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to identify regions with at least 20% tumor cell content in lung cancer tumors by using spectral parameters from dual-layer spectral detector computed tomography (SDCT) to design the puncture path for transthoracic lung biopsy (TTLB).

MATERIALS AND METHODS: This prospective study recruited patients with suspected lung cancer. Forty-one patients were enrolled to identify the high tumor cell proportion region (HTPR) and then another 15 patients to validate the accuracy of the HTPR. In each of the 41 patients, the suspected regions with high or low tumor cell proportions were punctured according to local iodine density (IoD) values for separate biopsies. The tumor cell proportions of 82 specimens were assessed and classified into high and low tumor cell proportions based on the threshold value of 20 %. The performance of spectral parameters was analyzed to distinguish the HTPR (tumor cell proportion ≥ 20 %) from the low tumor cell proportion region (LTPR). The cutoff value of optimal spectral parameter was used to prospectively guide the biopsy of the HTPR in 15 cases for further validation, and then the accuracy was calculated.

RESULTS: The AUC values of spectral parameters were all higher than those of CTconventional in identifying the HTPR (all P < 0.05). The IoD with a cutoff value of 0.59 mg/mL in arterial phase (AP) yielded good performance (specificity: 97.10 %) in identifying the HTPR. It was applied to 15 cases for validation, and the accuracy rate was 100 %.

CONCLUSION: Spectral CT parameters can be used to identify regions with at least 20% tumor cell content in lung cancer for biopsies.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ma, Li, Huang, et al. Role of iodine density value on dual-energy CT for detection of high tumor cell proportion region in lung cancer during CT-guided transthoracic biopsy. Eur J Radiol. 2023. PMID: 36669332. doi:10.1016/j.ejrad.2023.110689

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。