文献速递妇产影像MR

多序列MRI影像组学模型预测子宫内膜癌微卫星不稳定状态

Multisequence magnetic resonance imaging-based radiomics models for the prediction of microsatellite instability in endometrial cancer.
PubMed 文献 · Radiol Med · 2023-01-19

本回顾性多中心研究纳入338例子宫内膜癌患者,基于T2WI、DWI和增强T1WI提取影像组学特征,经ComBat harmonisation和Boruta选择9个特征,比较LR、RF和SVM三种分类器,SVM模型在外部验证组AUC达0.937,显示多序列MRI影像组学有望术前预测MSI状态。

要点

  • SVM模型外部验证AUC为0.937,训练组0.921,内部验证组0.903。
  • ComBat harmonisation可提高MSI预测性能。
  • 决策曲线分析示SVM在阈值0.581-0.783区间净收益更高。

核心结论

  • 多序列MRI影像组学模型在多中心背景下对子宫内膜癌MSI状态具有术前预测潜力。

研究设计与样本

  • 回顾性多中心研究,纳入338例子宫内膜癌患者,具备MSI状态和术前MRI。
  • 从T2WI、DWI和增强T1WI提取影像组学特征,采用ComBat harmonisation去除扫描仪间变异,Boruta算法选择关键特征。
  • 采用逻辑回归、随机森林和支持向量机三种分类算法构建模型,以AUC比较诊断性能,决策曲线分析评估临床实用性。

诊断标准与关键数值

  • 从1980个特征中Boruta最终选择9个影像组学特征。
  • SVM算法性能最佳,训练组、内部验证组和外部验证组的AUC分别为0.921、0.903和0.937。
  • 决策曲线分析显示SVM在阈值范围0.581-0.783内净收益高于其他分类器。

临床应用与阅片要点

  • 多序列MRI影像组学模型可作为术前无创预测子宫内膜癌MSI状态的辅助工具。
  • SVM模型在外部验证中表现稳定,但需注意ComBat harmonisation对多中心数据整合的作用。
  • 决策曲线分析提示SVM在特定阈值范围内具有较高临床净收益,但实际应用需结合临床情境。

局限性

  • 回顾性研究设计。
  • 原文未报告其他明显局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the performance of multisequence magnetic resonance imaging (MRI)-based radiomics models in the assessment of microsatellite instability (MSI) status in endometrial cancer (EC).

MATERIALS AND METHODS: This retrospective multicentre study included 338 EC patients with available MSI status and preoperative MRI scans, divided into training (37 MSI, 123 microsatellite stability [MSS]), internal validation (15 MSI, 52 MSS), and external validation cohorts (30 MSI, 81 MSS). Radiomics features were extracted from T2-weighted images, diffusion-weighted images, and contrast-enhanced T1-weighted images. The ComBat harmonisation method was applied to remove intrascanner variability. The Boruta wrapper algorithm was used for key feature selection. Three classification algorithms, logistic regression (LR), random forest (RF), and support vector machine (SVM), were applied to build the radiomics models. The area under the receiver operating characteristic curve (AUC) was calculated to compare the diagnostic performance of the models. Decision curve analysis (DCA) was conducted to determine the clinical usefulness of the models.

RESULTS: Among the 1980 features, Boruta finally selected nine radiomics features. A higher MSI prediction performance was achieved after running the ComBat harmonisation method. The SVM algorithm had the best performance, with AUCs of 0.921, 0.903, and 0.937 in the training, internal validation, and external validation cohorts, respectively. The DCA results showed that the SVM algorithm achieved higher net benefits than the other classifiers over a threshold range of 0.581-0.783.

CONCLUSION: The multisequence MRI-based radiomics models showed promise in preoperatively predicting the MSI status in EC in this multicentre setting.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Song, Luo, Ren, et al. Multisequence magnetic resonance imaging-based radiomics models for the prediction of microsatellite instability in endometrial cancer. Radiol Med. 2023. PMID: 36656410. doi:10.1007/s11547-023-01590-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。