声触诊弹性成像与声触诊定量技术无创评估大鼠门脉高压模型

Use of Sound Touch Elastography and Sound Touch Quantification for the Noninvasive Evaluation of Portal Hypertension in a Rat Model.
PubMed 文献 · J Ultrasound Med · 2023-01-13

本研究在60只CCl4诱导肝硬化门脉高压大鼠模型中,使用STE和STQ测量肝、脾硬度,并与门脉压力对比。结果显示肝脾硬度与门脉压力正相关(r=0.566-0.882,P<.001),STE和STQ对识别门脉高压具有较高AUC,尤其对PP≥10 mmHg。结论认为STE和STQ是评估门脉高压严重程度的可靠无创工具。

要点

  • 肝、脾STE和STQ测值与门脉压力正相关,可用于无创评估门脉高压。
  • 脾STE对PP≥5 mmHg的AUC最高(0.982),诊断价值突出。
  • STE和STQ对PP≥10 mmHg的识别能力最佳(AUC 0.938-0.967)。

诊断标准与关键数值

  • 肝、脾STE和STQ测值与门脉压力正相关(r=0.566-0.882,均P<.001)。
  • PP≥5 mmHg时,L-STE、S-STE、L-STQ、S-STQ的AUC分别为0.931(95%CI 0.847-1.000)、0.982(95%CI 0.956-1.000)、0.796(95%CI 0.680-0.912)、0.925(95%CI 0.858-0.993)。
  • PP≥10 mmHg时,L-STE、S-STE、L-STQ、S-STQ的AUC分别为0.937(95%CI 0.865-1.000)、0.938(95%CI 0.864-1.000)、0.967(95%CI 0.923-1.000)、0.960(95%CI 0.897-1.000)。
  • PP≥12 mmHg时,L-STE、S-STE、L-STQ、S-STQ的AUC分别为0.954(95%CI 0.897-1.000)、0.790(95%CI 0.652-0.928)、0.808(95%CI 0.680-0.935)、0.740(95%CI 0.595-0.885)。

临床应用与阅片要点

  • 肝、脾STE和STQ测值可用于无创评估门脉高压严重程度,脾STE对轻度门脉高压诊断价值较高。
  • STE和STQ对PP≥10 mmHg的识别能力最佳,可作为临床评估门脉高压的参考指标。

局限性

  • 本研究为动物模型(CCl4诱导肝硬化大鼠),结果外推至人类需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In this study, we used the recently developed ultrasound elastography techniques sound touch elastography (STE) and sound touch quantification (STQ) to quantify portal hypertension (PHT) severity in a rat model of carbon tetrachloride (CCl4 )-induced cirrhotic PHT.

METHODS: In total, 60 rats were used. Various degrees of PHT were established. Liver and spleen stiffness were measured by STE (L-STE and S-STE, respectively) and STQ (L-STQ and S-STQ, respectively). We measured portal pressure (PP) after ultrasonographic examination. The performance of the STE and STQ parameters in the identification of PHT was evaluated using receiver operating characteristic (ROC) analyses.

RESULTS: Liver and spleen stiffness measurements obtained with STE and STQ correlated positively with the PP (r = 0.566-0.882, all P < .001). The areas under ROC curves for L-STE, S-STE, L-STQ, and S-STQ values were 0.931 (95% confidence interval [CI], 0.847-1.000), 0.982 (95% CI, 0.956-1.000), 0.796 (95% CI, 0.680-0.912), and 0.925 (95% CI, 0.858-0.993), respectively, for PP ≥5 mmHg; 0.937 (95% CI, 0.865-1.000), 0.938 (95% CI, 0.864-1.000), 0.967 (95% CI, 0.923-1.000), and 0.960 (95% CI, 0.897-1.000), respectively, for PP ≥10 mmHg; and 0.954 (95% CI, 0.897-1.000), 0.790 (95% CI, 0.652-0.928), 0.808 (95% CI, 0.680-0.935), and 0.740 (95% CI, 0.595-0.885), respectively, for PP ≥12 mmHg.

CONCLUSIONS: STE and STQ are reliable noninvasive tools for the assessment of PHT severity, especially for PP ≥10 mmHg, in a rat model of CCl4 -induced cirrhotic PHT.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Dong, Lyu, Wang, et al. Use of Sound Touch Elastography and Sound Touch Quantification for the Noninvasive Evaluation of Portal Hypertension in a Rat Model. J Ultrasound Med. 2023. PMID: 36637111. doi:10.1002/jum.16172

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。