基于深度学习的乳腺MRI自动诊断:Mask R-CNN检测联合ResNet50分类
本研究采用Mask R-CNN检测乳腺MRI可疑病灶,再用ResNet50基于三个DCE参数图评估恶性概率。第一数据集灵敏度96%(99/103),ResNet50可消除约80%的假阳性;第二数据集独立测试灵敏度81%(43/53)。联合模型有望发展为全自动计算机辅助诊断系统。
要点
- Mask R-CNN联合ResNet50可实现乳腺MRI病灶自动检测与分类。
- ResNet50可消除Mask R-CNN检测出的约80%假阳性。
- 第一数据集灵敏度96%,第二数据集独立测试灵敏度81%。
核心结论
- ResNet50可消除Mask R-CNN检测出的约80%假阳性,联合模型有望发展为全自动乳腺MRI计算机辅助诊断系统。
研究设计与样本
- 研究使用两个数据集:第一集176例(103恶性、73良性),第二集84例(53恶性、31良性)用于独立测试。
- 检测阶段以预对比图像和左右乳腺减影图像为输入以考虑对称性,分类阶段以三个DCE参数图为输入,切片分析结果合并为病灶级诊断。
诊断标准与关键数值
- 第一数据集Mask R-CNN检出103例癌症中的101例,ResNet50正确分类101例中的99例,灵敏度99/103=96%。
- 第一数据集73个良性病灶中48个及131个正常区域被检为可疑,经ResNet50分类后仅16个良性病灶和16个正常区域仍判为恶性。
- 第二数据集独立测试灵敏度43/53=81%;121个被检出的非癌病灶中,仅6个良性病灶和22个正常组织被判为恶性。
临床应用与阅片要点
- 阅片时可参考联合模型减少假阳性的能力,但独立测试灵敏度81%提示仍需人工复核。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Diagnosis of breast cancer on MRI requires, first, the identification of suspicious lesions; second, the characterization to give a diagnostic impression. We implemented Mask Reginal-Convolutional Neural Network (R-CNN) to detect abnormal lesions, followed by ResNet50 to estimate the malignancy probability.
MATERIALS AND METHODS: Two datasets were used. The first set had 176 cases, 103 cancer, and 73 benign. The second set had 84 cases, 53 cancer, and 31 benign. For detection, the pre-contrast image and the subtraction images of left and right breasts were used as inputs, so the symmetry could be considered. The detected suspicious area was characterized by ResNet50, using three DCE parametric maps as inputs. The results obtained using slice-based analyses were combined to give a lesion-based diagnosis.
RESULTS: In the first dataset, 101 of 103 cancers were detected by Mask R-CNN as suspicious, and 99 of 101 were correctly classified by ResNet50 as cancer, with a sensitivity of 99/103 = 96%. 48 of 73 benign lesions and 131 normal areas were identified as suspicious. Following classification by ResNet50, only 16 benign and 16 normal areas remained as malignant. The second dataset was used for independent testing. The sensitivity was 43/53 = 81%. Of the total of 121 identified non-cancerous lesions, only 6 of 31 benign lesions and 22 normal tissues were classified as malignant.
CONCLUSION: ResNet50 could eliminate approximately 80% of false positives detected by Mask R-CNN. Combining Mask R-CNN and ResNet50 has the potential to develop a fully-automatic computer-aided diagnostic system for breast cancer on MRI.
引用
- Zhang, Liu, Nie, et al. Deep Learning-based Automatic Diagnosis of Breast Cancer on MRI Using Mask R-CNN for Detection Followed by ResNet50 for Classification. Acad Radiol. 2023. PMID: 36631349. doi:10.1016/j.acra.2022.12.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。