文献速递胸部CT

环形周边高碘浓度在双能CT鉴别原发性肺癌与肺转移瘤中的价值

Ringlike Peripheral Increased Iodine Concentration for the Differentiation of Primary Lung Cancer and Pulmonary Metastases on Contrast-Enhanced Dual-Energy CT.
PubMed 文献 · AJR Am J Roentgenol · 2023-01-11

回顾性纳入93例经手术切除的肺部实性病变患者,比较环形周边高碘浓度与常规征象在双能CT鉴别原发性肺癌与肺转移瘤中的价值。肺转移瘤环形周边高碘浓度出现率显著高于原发肺癌(52% vs 19%),该征象诊断转移瘤特异度81%、敏感度52%,是多变量分析中唯一独立预测因子(OR 7.81)。

要点

  • 环形周边高碘浓度诊断肺转移瘤特异度高(81%)但敏感度低(52%)。
  • 该征象观察者间一致性好(kappa 0.80),优于毛刺、空气支气管征和边缘强化。
  • 日常阅片发现环形周边高碘浓度时应警惕转移瘤可能。

关键影像表现/征象

  • 肺转移瘤环形周边高碘浓度出现率52%,显著高于原发肺癌19%(p=.004)。
  • 毛刺边缘出现率转移瘤49% vs 原发肺癌32%(p=.17),差异无统计学意义。
  • 空气支气管征出现率转移瘤36% vs 原发肺癌51%(p=.24),差异无统计学意义。
  • 边缘强化出现率两组均为4%(p>.99),差异无统计学意义。

诊断标准与关键数值

  • 环形周边高碘浓度诊断肺转移瘤:敏感度52%、特异度81%。
  • 无毛刺边缘诊断肺转移瘤:敏感度68%、特异度49%。
  • 无空气支气管征诊断肺转移瘤:敏感度64%、特异度51%。
  • 存在边缘强化诊断肺转移瘤:敏感度4%、特异度96%。
  • 多变量分析中环形周边高碘浓度预测肺转移瘤的OR为7.81(95%CI 2.28-29.60),p=.001。

局限性

  • 回顾性单中心研究,样本量有限(93例,转移瘤25例)。
  • 部分征象观察者间一致性较低(毛刺边缘kappa 0.26),可能影响结果稳定性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Differentiation of primary lung cancers and pulmonary metastases may present a diagnostic dilemma given overlapping CT findings. OBJECTIVE. The purpose of this study was to compare the utility of ringlike peripheral increased iodine concentration and conventional findings for differentiating primary lung cancers from pulmonary metastases on dual-energy CT (DECT). METHODS. This retrospective study included 93 patients (64 men, 29 women; median age, 70 years) who underwent resection of a primary lung cancer (n = 68) or pulmonary metastasis (n = 25) corresponding to a solid lesion on preoperative contrast-enhanced DECT performed between April 2020 and March 2021. Venous phase 120-keV single-energy images, equilibrium phase 66-keV virtual monoenergetic images, and iodine concentration maps were reconstructed. Two radiologists independently assessed lesions for spiculated margins, air bronchograms, rim enhancement, and thin ringlike peripheral high iodine concentration; differences were resolved by consensus. Inter-reader agreement and diagnostic performance were assessed. Multivariable logistic regression analysis incorporated additional patient and lesion characteristics. RESULTS. Interobserver agreement, expressed as kappa, was 0.26 for spiculated margins, 0.60 for air bronchograms, 0.56 for rim enhancement, and 0.80 for ringlike peripheral high iodine concentration. Pulmonary metastases, compared with primary lung cancers, exhibited significantly higher frequency of ringlike peripheral high iodine concentration (52% vs 19%; p = .004) but no significant difference in frequency of spiculated margins (49% vs 32%; p = .17), air bronchograms (36% vs 51%; p = .24), or rim enhancement (4% vs 4%; p > .99). Sensitivity and specificity for diagnosing pulmonary metastasis were 68% and 49% for absence of spiculated margins, 64% and 51% for absence of air bronchograms, 4% and 96% for presence of rim enhancement, and 52% and 81% for presence of ringlike peripheral high iodine concentration. In multivariable analysis including smoking history, lesion diameter, multiple resected lesions, and ringlike peripheral high iodine concentration, the only independent significant predictor of pulmonary metastasis was ringlike peripheral high iodine concentration (OR, 7.81 [95% CI, 2.28-29.60); p = .001). CONCLUSION. Ringlike peripheral high iodine concentration had excellent interobserver agreement and high specificity (albeit poor sensitivity) for differentiating pulmonary metastasis from primary lung cancer and was independently predictive of pulmonary metastasis. CLINICAL IMPACT. Ringlike peripheral high iodine concentration could help guide management of patients with known cancer and an indeterminate solitary nodule.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Sato, Ishiyama, Nakano, et al. Ringlike Peripheral Increased Iodine Concentration for the Differentiation of Primary Lung Cancer and Pulmonary Metastases on Contrast-Enhanced Dual-Energy CT. AJR Am J Roentgenol. 2023. PMID: 36629308. doi:10.2214/AJR.22.28654

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。