文献速递骨肌MR

超高场强腕关节MRI的临床应用:3T与7T多阅片者比较研究

Clinical Application of Ultrahigh-Field-Strength Wrist MRI: A Multireader 3-T and 7-T Comparison Study.
PubMed 文献 · Radiology · 2023-01-10

该前瞻性多阅片者研究纳入25名健康对照和25名慢性腕痛患者,同日行3T与7T腕关节MRI,由7名骨肌放射科医生对图像质量、伪影、脂肪抑制及软骨、三角纤维软骨复合体(TFCC)、腕骨间韧带的显示进行半定量评分。结果显示7T在整体图像质量和PD压脂序列伪影方面更优,且软骨显示更佳;但T1、T2序列及脂肪抑制均匀性、TFCC和腕骨间韧带显示以3T更优。

要点

  • 7T在PD压脂序列显示软骨方面具有优势,可作为评估腕关节软骨的补充序列。
  • TFCC及舟月、月三角韧带的显示3T优于7T,常规评估这些结构仍以3T为主。
  • 7T在T1和T2序列的图像质量及脂肪抑制均匀性上不如3T,需注意序列选择。

关键影像表现/征象

  • 7T在PD压脂序列上整体图像质量更优(P = .002)且伪影更少。
  • 3T在T1和T2加权序列图像质量更优(均P < .001),脂肪抑制均匀性也更优(P < .001)。
  • 7T对软骨的显示优于3T(P < .001)。
  • 3T对TFCC(P < .001)、舟月韧带(P = .048)和月三角韧带(P = .04)的显示优于7T。

诊断标准与关键数值

  • 阅片者间信度对病变检出为轻度至中等一致(κ = 0.20-0.64)。

临床应用与阅片要点

  • 日常阅片可优先使用3T评估TFCC和腕骨间韧带,7T可作为软骨评估的补充。
  • 7T PD压脂序列伪影较少,但T1和T2序列及脂肪抑制均匀性不及3T,需注意序列选择。
  • 报告时应结合序列优势判断病变显示可靠性,避免因场强差异误判。

局限性

  • 仅纳入健康对照和慢性腕痛患者,未涵盖其他腕关节病变。
  • 阅片者间信度仅为轻度至中等,一致性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. Materials and Methods In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. Results In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). Conclusion A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. © RSNA, 2023 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Heiss, Weber, Balbach, et al. Clinical Application of Ultrahigh-Field-Strength Wrist MRI: A Multireader 3-T and 7-T Comparison Study. Radiology. 2023. PMID: 36625744. doi:10.1148/radiol.220753