本研究基于机构数据估算CT检查中碘对比剂浪费量,比较单剂量与多剂量包装的对比剂浪费、塑料浪费及财务成本。结果显示单剂量100mL瓶平均每次CT浪费19.7mL,年浪费超964L;

要点

  • 单剂量100mL碘对比剂瓶平均每例CT浪费19.7mL,年浪费超964L。
  • 多剂量系统预计减少药物浪费至少73%、塑料浪费约93%。

核心结论

  • 多剂量碘对比剂包装可节约对比剂、减少塑料浪费并带来显著财务节省。

研究设计与样本

  • 基于单中心机构数据的建模研究,比较单剂量与多剂量碘对比剂输送系统的浪费与成本。
  • 使用机构数据估算每例CT平均对比剂用量、浪费量及年总浪费量;多剂量瓶浪费按每例平均用量应用于更大瓶容量推算。
  • 称重单剂量瓶、多剂量瓶及注射器以计算塑料浪费;财务分析比较两种系统的耗材成本。

诊断标准与关键数值

  • 单剂量100mL碘对比剂瓶平均每例CT浪费19.7mL,年浪费超过964L。
  • 多剂量系统预计减少药物浪费至少73%,减少塑料浪费约93%。

临床应用与阅片要点

  • 在CT对比剂使用中可考虑多剂量包装以减少对比剂废弃和塑料垃圾。
  • 多剂量系统可降低耗材成本,但需评估资本投入与工作流程适配。

局限性

  • 基于单中心机构数据的建模估算,结果外推需谨慎。
  • 多剂量瓶浪费为基于平均用量的推算,非直接实测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Iodinated contrast media (ICM) is used in computed tomography (CT) imaging to better visualize pathophysiology. ICM is commonly sold in "single-dose" bottles that require any unused volume to be discarded. Multi-dose bottles have been developed as an alternative packaging method. The objective of this study was to compare ICM waste, plastic waste, and the associated financial costs for both the single-dose and multi-dose ICM delivery systems.

METHODS: Institutional data was used to estimate the average ICM administered per CT scan, average ICM wasted per CT scan, and the total ICM volume wasted annually. Waste estimates for the multi-dose bottles were generated by applying the average ICM administered per CT scan to the larger, multi-dose bottle volumes. Single-dose bottles, multi-dose bottles and injection syringes were weighed and used to calculate plastic waste generated by both packaging methods. Financial analysis was performed to compare the cost of supplies for single-dose and multi-dose ICM delivery systems.

RESULTS: We found that 100 mL single-dose ICM bottles waste an average of 19.7 mL per CT scan, representing over 964 L of ICM wasted per year. The multi-dose ICM delivery system was projected to decrease pharmaceutical waste by at least 73% and reduce plastic waste by approximately 93%. We also estimate $494,000 in annual savings using the multi-dose ICM delivery method at our institution.

CONCLUSION: Multi-dose ICM packaging can help conserve ICM, an important pharmaceutical that was only recently severely affected supply chain disruptions. The multi-dose delivery system can also reduce plastic waste and generate substantial financial savings to offset capital investment.