文献速递骨肌儿科影像MR

5岁时髋关节筛查结局的新型MRI参数组内与组间观察者变异

Intra- and interobserver variability of novel magnetic resonance imaging parameters for hip screening and treatment outcomes at age 5 years.
PubMed 文献 · Pediatr Radiol · 2023-01-09

该研究评估5岁儿童无镇静MRI作为髋关节筛查结局指标的可行性,共134名儿童中132名获得诊断图像,测量骨性/软骨性髋臼指数及外侧髋臼顶切线斜率等参数,发现外侧髋臼顶相关参数观察者变异较大但与治疗开始年龄负相关,而传统髋臼指数无显著相关。

要点

  • 5岁儿童无镇静MRI用于髋筛查结局评估可行,132/134获得诊断图像
  • 外侧髋臼顶参数比骨性/软骨性髋臼指数观察者变异更大
  • 外侧髋臼顶切线斜率与治疗开始年龄负相关,或更好反映髋臼充分性

核心结论

  • 5岁时无镇静MRI可作为髋关节筛查项目的结局评估手段。
  • 外侧髋臼顶相关参数尽管观察者变异较大,但可能比软骨性和骨性髋臼指数更好地反映髋臼充分性。

研究设计与样本

  • 前瞻性可行性研究,纳入治疗或监测期间接受过至少一次超声检查的婴儿,在5岁时邀请进行无镇静MRI扫描。
  • 共134名儿童受邀,132名获得诊断图像。
  • 测量参数包括骨性髋臼指数、软骨性髋臼指数、外侧骨性髋臼顶切线相对于Hilgenreiner线的下斜度,以及通过髋臼顶点至髋臼缘的线的下斜度。
  • 评估组内和组间观察者变异,并分析各参数与治疗开始年龄的相关性。

诊断标准与关键数值

  • 骨性髋臼指数均值(标准差):右侧16.6°(3.3),左侧17.8°(3.2)。
  • 外侧骨性髋臼顶切线相对于Hilgenreiner线的下斜度均值(标准差):右侧10.4°(4.5),左侧9.0°(4.3)。
  • 通过髋臼顶点至髋臼缘的线下斜度均值(标准差):右侧3.7°(4.6),左侧3.9°(4.7)。
  • 外侧髋臼顶切线斜率与治疗开始年龄在双侧均呈显著负相关,而骨性/软骨性髋臼指数及顶点-边缘指数无显著相关。

临床应用与阅片要点

  • 在5岁儿童髋关节MRI结局评估中,可考虑测量外侧髋臼顶切线斜率以补充传统髋臼指数。
  • 需注意外侧髋臼顶参数观察者变异较大,报告时应结合骨性和软骨性髋臼指数综合判断。
  • 无镇静MRI在5岁儿童中可行性高,可作为髋筛查项目随访的影像学结局工具。

局限性

  • 原文未明确报告研究类型(如单中心或回顾性)及具体局限性描述。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The outcome measure of neonatal hip screening is usually the radiographic acetabular index.

OBJECTIVE: To assess the feasibility of magnetic resonance imaging (MRI) without sedation and compare the utility of outcome parameters measured from MRI images.

MATERIALS AND METHODS: The invitation for MRI scanning at 5 years of age was incorporated into follow-up for babies who had more than one ultrasound examination during treatment or surveillance.

RESULTS: Diagnostic images were obtained in 132 of 134 children. The mean osseous acetabular index (standard deviation [SD]) was 16.6 (3.3) degrees for the right hip and 17.8 (3.2) for the left; the values for the cartilaginous acetabular index were 3.1 (3) and 3.4 (3.2). The mean downslope of a tangent to the lateral bony acetabular roof was 10.4 (4.5) and 9.0 (4.3) with respect to Hilgenreiner's line and that of a line drawn through the apex to the margin of the acetabulum was 3.7 (4.6) and 3.9 (4.7). Intra- and interobserver variation was greater for measures specific to the lateral acetabular roof than for ossific and cartilaginous indices. There was significant negative correlation between the downslope of the tangent to the lateral roof index and the age at onset of treatment on both sides, but no significant correlation for ossific or cartilaginous acetabular indices or apex-marginal index.

CONCLUSION: MRI without sedation at 5 years of age is feasible as an outcome measure for hip screening programmes. Parameters specific to the lateral acetabulum may better reflect acetabular sufficiency, despite having greater observer variation than cartilaginous and ossific acetabular indices.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Wilkinson, Wilkinson, Elton, et al. Intra- and interobserver variability of novel magnetic resonance imaging parameters for hip screening and treatment outcomes at age 5 years. Pediatr Radiol. 2023. PMID: 36622404. doi:10.1007/s00247-022-05565-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。