这项前瞻性研究纳入120例疑似心肌病患者,在3 T上对比常规分辨率与高分辨率二维LGE序列(IR和PSIR)的图像质量。体模中仅高分辨率图像可检出小于1 mm的特征;体内高分辨率LGE分辨率评分4.14-4.24高于常规分辨率2.99(P < .05),边界锐度更高(P < .001)。ROC分析未发现两者LGE检出性能存在差异,IR和PSIR幅度图像的LGE对比噪声比也无变化证据。

要点

  • 高分辨率IR和PSIR幅度序列在体内外均显示最高分辨率。
  • 高分辨率LGE可检出体模中小于1 mm的特征,常规分辨率不能。
  • LGE检出性能与对比噪声比在常规与高分辨率间无差异证据。

关键影像表现/征象

  • 体模中仅高分辨率图像可检出小于1 mm的特征。
  • 体内高分辨率LGE图像分辨率评分为4.14-4.24,高于常规分辨率参考评分2.99(P < .05)。
  • 高分辨率图像边界锐度更高(P < .001)。

诊断标准与关键数值

  • 采用五点评分系统定性评估体内图像质量与分辨率。
  • 以常规分辨率IR图像为参考,计算高增强区与远端心肌的对比噪声比及LGE检出性能。
  • ROC曲线分析未发现常规分辨率与高分辨率图像间LGE检出存在差异的证据。
  • IR和PSIR幅度图像中LGE的对比噪声比与参考图像相比无变化证据。

临床应用与阅片要点

  • 高分辨率二维LGE(尤其IR和PSIR幅度序列)可提升图像分辨率和边界锐度,利于显示细小病灶。
  • 在疑似心肌病患者的LGE评估中,可考虑使用高分辨率序列替代常规分辨率而不必担心检出性能下降。

局限性

  • 单中心前瞻性研究,样本量120例,结论外推需谨慎。
  • 仅使用3 T设备,未评估其他场强下的表现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the image quality of high-spatial-resolution two-dimensional (2D) late gadolinium enhancement (LGE) cardiac MRI compared with conventional normal-resolution LGE MRI.

MATERIALS AND METHODS: This prospective study included participants suspected of having cardiomyopathy who underwent cardiac MRI between March 2021 and December 2021. Normal-resolution and high-resolution 2D LGE sequences (inversion recovery [IR] and phase-sensitive inversion recovery [PSIR]) were performed at 3 T. Resolution was compared between normal-resolution and high-resolution images obtained in a quality assurance phantom. In vivo image quality and resolution were evaluated qualitatively using a five-point scoring system. Receiver operating characteristic curve analysis was used for LGE detection performance. Border sharpness was assessed with profile curve measurement. The contrast-to-noise ratio (CNR) between hyperenhancement and remote myocardium and LGE detection performance were calculated using normal-resolution IR images as the reference.

RESULTS: In total, 120 participants were evaluated (mean age, 56 years ± 17 [SD]; 72 men). Features smaller than 1 mm were detectable only on high-resolution images of the phantom. In vivo, the image resolution score with high-resolution LGE was 4.14-4.24, which was higher than the normal-resolution LGE reference score of 2.99 (P < .05). Border sharpness was higher in high-resolution images (P < .001). Receiver operating characteristic curve analysis revealed no evidence of a difference in LGE detection between normal-resolution and high-resolution images. There was also no evidence of a change in CNR of LGE in IR and PSIR magnitude compared with reference images.

CONCLUSION: Comparison of image quality in 2D high-resolution and normal-resolution LGE cardiac MRI demonstrated the highest resolution for high-resolution IR and high-resolution PSIR magnitude sequences.Keywords: Cartilage Imaging, MRI, Cardiac, Heart, Imaging Sequences, Comparative Studies Supplemental material is available for this article. © RSNA, 2022.