文献速递妇产影像腹部MR

基于MRI影像组学列线图预测高危胎盘植入谱系患者术中大量出血

MRI-based radiomics nomogram in patients with high-risk placenta accreta spectrum: can it aid in the prenatal diagnosis of intraoperative blood loss?
PubMed 文献 · Abdom Radiol (NY) · 2023-01-05

列线图在训练集和验证集的AUC分别为0.866和0.876,优于影像组学模型和临床模型,验证集准确度0.844、敏感度0.882、特异度0.830,决策曲线分析证实其临床实用性。

要点

  • 列线图可无创预测高危PAS患者术中大量出血风险。
  • 验证集列线图AUC为0.876,敏感度0.882,特异度0.830。
  • 列线图性能优于单纯临床模型和影像组学模型。

核心结论

  • 基于MRI影像组学与临床特征构建的列线图可无创预测高危PAS患者术中大量出血,并指导产科医生制定合理的术前治疗方案。

研究设计与样本

  • 基于矢状位T2加权HASTE图像手动勾画胎盘感兴趣区提取定量影像组学特征,并分析临床特征。
  • 构建临床模型、影像组学模型和列线图,采用AUC和DeLong检验评估诊断性能,决策曲线分析评估临床效用。

诊断标准与关键数值

  • 列线图在训练集和验证集的AUC分别为0.866和0.876,影像组学模型分别为0.821和0.855,临床模型分别为0.685和0.619。
  • 列线图与临床模型及影像组学模型比较,DeLong检验P<0.05。
  • 验证集中列线图鉴别术中大量出血的准确度为0.844,敏感度为0.882,特异度为0.830。

临床应用与阅片要点

  • 对于高危PAS患者,可基于矢状位T2加权HASTE图像提取胎盘影像组学特征,结合临床特征使用列线图术前评估术中大量出血风险。
  • 列线图预测风险较高者,可提示产科医生提前制定更充分的术前准备和出血应对方案。

局限性

  • 研究为回顾性设计,训练集和验证集分别来自两家医院,样本量有限。
  • 影像组学特征仅基于矢状位T2加权HASTE序列提取,未纳入其他MRI序列。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and validate the nomogram by combining MRI-derived radiomics and clinical features for preoperatively predicting massive intraoperative blood loss (IBL) in high-risk placenta accreta spectrum (PAS) patients.

METHODS: A total of 152 high-risk PAS patients from Hospital A were enrolled and constituted the training cohort, and 64 patients from Hospital B constituted the validation cohort. Clinical features were analyzed retrospectively. Placental regions of interest were manually positioned on sagittal T2-weighted HASTE images for each patient to extract quantitative radiomics features. Clinical model, radiomics model, and nomogram were built to predict the risk of massive IBL. The diagnostic performance was assessed using the area under the receiver operating characteristic curve (AUC) and the DeLong test. Decision curve analysis (DCA) was performed to determine the performance of the best predictive model.

RESULTS: The nomogram (AUC = 0.866 and 0.876, respectively) and radiomics model (AUC = 0.821 and 0.855, respectively) outperformed the clinical model (AUC = 0.685 and 0.619, respectively) both in the training and validation cohorts (Delong test, P < 0.05). Furthermore, the nomogram performed best with an accuracy of 0.844, sensitivity of 0.882, and specificity of 0.830 for differentiating massive IBL in the validation cohort. DCA confirmed the clinical utility of the nomogram.

CONCLUSION: The nomogram can be used to noninvasively predict massive IBL patients and guide obstetricians to make reasonable preoperative treatment plans.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang, Hu, Wen, et al. MRI-based radiomics nomogram in patients with high-risk placenta accreta spectrum: can it aid in the prenatal diagnosis of intraoperative blood loss? Abdom Radiol (NY). 2023. PMID: 36604318. doi:10.1007/s00261-022-03784-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。