低kVp与双能CT结合深度学习图像重建在胰腺导管腺癌显示中的比较
回顾性分析111例行胰腺协议CT的患者,比较80-kVp与双能CT 40-keV虚拟单能图像(均使用中等强度DLIR)的图像质量和胰腺导管腺癌(PDAC)显示清晰度。结果显示40-keV组血管和实质器官CT值、背景噪声更高,但SNR和肿瘤-胰腺CNR更高,PDAC显示更优,且两组剂量长度乘积(DLP)无显著差异。
要点
- 40-keV虚拟单能图像在相同DLP下可提高PDAC与胰腺的对比噪声比,改善肿瘤显示。
- 40-keV图像背景噪声较高,但主观图像质量与80-kVp无显著差异。
- 40-keV组血管和实质器官CT值更高,可能影响窗宽窗位设置。
关键影像表现/征象
- 40-keV组血管和实质器官CT值高于80-kVp组(所有P<.001)。
- 40-keV组胰腺期和门静脉期的背景噪声均高于80-kVp组(P<.001)。
- 40-keV组所有解剖结构的SNR更高(P<.001-0.005),但 reviewer 2 的肝脏SNR除外(P=.47)。
- 40-keV组肿瘤-胰腺CNR更高(P<.001-0.01)。
- 40-keV组PDAC显示清晰度优于80-kVp组(P=.007-0.03)。
诊断标准与关键数值
- PDAC显示清晰度在40-keV组优于80-kVp组(P=.007-0.03)。
- 40-keV组肿瘤-胰腺CNR高于80-kVp组(P<.001-0.01)。
- 两组图像质量在胰腺期和门静脉期无差异(P=.30-0.90)。
- 胰腺期DLP:40-keV组275 mGy*cm vs. 80-kVp组313 mGy*cm(P=.05);门静脉期DLP:743 mGy*cm vs. 766 mGy*cm(P=.20)。
临床应用与阅片要点
- 在胰腺协议CT中,可考虑使用40-keV虚拟单能图像结合中等强度DLIR以提高PDAC的显示清晰度。
- 40-keV图像背景噪声较高,阅片时需注意调整窗宽窗位以优化图像质量。
- 40-keV图像血管和实质器官CT值更高,可能影响对强化程度的判断。
局限性
- 回顾性研究设计。
- 单中心研究。
- 样本量有限(共111例,PDAC病例数较少)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the image quality and conspicuity of pancreatic ductal adenocarcinoma (PDAC) between the low-kVp and dual-energy pancreatic protocol CT reconstructed with deep-learning image reconstruction (DLIR).
METHOD: A cohort of 111 consecutive patients (median age, 72 years; 56 men) undergoing a pancreatic protocol CT were retrospectively analyzed. Among them, 58 patients underwent 80-kVp CT (80-kVp group), and 53 patients underwent dual-energy CT and reconstructed at 40-keV (40-keV group). The medium-strength level of DLIR were used in both groups. Quantitative measurements, qualitative image quality, PDAC conspicuity, and dose-length product (DLP) were compared between the two groups using Mann-Whitney U test.
RESULTS: A total of 20 and 16 PDACs were found in the 80-kVp and 40-keV groups, respectively. CT numbers of the vasculatures and parenchymal organs (P <.001 for all) and the background noise at both pancreatic and portal venous phases (P <.001) were higher in the 40-keV group than in the 80-kVp group. The signal-to-noise ratio (SNR) of all anatomical structures (P <.001-0.005), except for the liver in reviewer 2 (P =.47), and the tumor-to-pancreas contrast-to-noise ratio (CNR; P <.001-0.01) were higher in the 40-keV group than in the 80-kVp group. No difference was found in the image quality at both phases (P =.30-0.90). PDAC conspicuity was better in the 40-keV group than in the 80-kVp group (P =.007-0.03). DLP at pancreatic (275 vs. 313 mGy*cm; P =.05) and portal venous phases (743 vs. 766 mGy*cm; P =.20) was comparable between the two groups.
CONCLUSION: Under the same DLP, virtual monoenergetic images at 40-keV demonstrated higher SNR and tumor-to-pancreas CNR and better PDAC conspicuity compared to the 80-kVp setting.
引用
- Noda, Takai, Asano, et al. Comparison of image quality and pancreatic ductal adenocarcinoma conspicuity between the low-kVp and dual-energy CT reconstructed with deep-learning image reconstruction algorithm. Eur J Radiol. 2022. PMID: 36603479. doi:10.1016/j.ejrad.2022.110685
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。