文献速递心血管MR

三维全心心脏MRI序列用于测量左心室心肌致密化不全

Three-dimensional Whole-Heart Cardiac MRI Sequence for Measuring Trabeculation in Left Ventricular Noncompaction.
PubMed 文献 · Radiol Cardiothorac Imaging · 2022-11-17

结果显示三维全心MRI图像质量更高,结构判别更好,观察者间一致性优于二维电影MRI。

要点

  • 三维全心MRI在左心室心肌致密化不全测量中观察者间一致性优于二维电影MRI。
  • 短轴测量的一致性高于长轴测量,三维序列在短轴ICC可达0.96-0.98。
  • 三维全心MRI图像质量评分显著高于二维电影MRI(P < .001)。

核心结论

  • 三维全心MRI图像质量更高,结构判别更好,观察者间一致性优于标准二维电影MRI,适用于左心室心肌致密化不全的测量。

研究设计与样本

  • 图像质量按3级评分(1=优,2=合格,3=无法诊断),评估非致密心肌与致密心肌及致密心肌与邻近组织的区分度。
  • 统计方法包括Pearson、Spearman和组内相关系数检验。

诊断标准与关键数值

  • 长轴测量中,两序列间致密心肌相关系数为Pearson 0.66-0.79、Spearman 0.61-0.68,非致密心肌为Pearson 0.90-0.97、Spearman 0.77-0.91。
  • 长轴测量三维全心MRI的ICC:致密心肌0.90(95% CI: 0.78, 0.95),非致密心肌0.94(95% CI: 0.84, 0.97);二维电影MRI的ICC:致密心肌0.77(95% CI: 0.55, 0.89),非致密心肌0.87(95% CI: 0.72, 0.94)。
  • 短轴测量中,两序列间致密心肌和非致密心肌相关系数为Pearson 0.86-0.98、Spearman 0.82-0.98。
  • 短轴测量三维全心MRI的ICC:致密心肌0.96(95% CI: 0.94, 0.99),非致密心肌0.98(95% CI: 0.97, 0.99);二维电影MRI的ICC:致密心肌0.82(95% CI: 0.63, 0.92),非致密心肌0.87(95% CI: 0.72, 0.94)。
  • 三维全心MRI图像质量高于二维电影MRI(P < .001)。

临床应用与阅片要点

  • 在左心室心肌致密化不全评估中,可优先采用三维全心MRI短轴测量以提高观察者间一致性。
  • 三维全心MRI对非致密心肌与致密心肌及邻近组织的区分度更优,有助于减少测量误差。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare three-dimensional (3D) whole-heart MRI with isotropic submillimeter resolution with standard two-dimensional (2D) cine MRI in measuring the bilayered myocardium in left ventricular noncompaction (LVNC).

MATERIALS AND METHODS: Twenty-four patients with LVNC (mean age, 42 years ± 16 [SD]) were retrospectively enrolled between October 2011 and July 2020. Compacted myocardium (CM) and noncompacted myocardium (NCM) were measured in long axis (Petersen approach) and short axis (Jacquier approach) at 3D whole-heart and 2D cine MRI by two independent readers. Image quality (1 = excellent, 2 = adequate, 3 = nondiagnostic), considering discrimination between NCM and CM and CM and adjacent tissue, was evaluated. Pearson, Spearman, and intraclass correlation tests were used as statistical tests.

RESULTS: In long-axis measurements, the correlation between both sequences was moderate to strong for CM (Pearson, 0.66-0.79; Spearman, 0.61-0.68) and strong to very strong for NCM (Pearson, 0.90-0.97; Spearman, 0.77-0.91). Intraclass correlation coefficient (ICC) in 3D whole-heart MRI was 0.90 (95% CI: 0.78, 0.95) for CM and 0.94 (95% CI: 0.84, 0.97) for NCM, while ICC in 2D cine MRI was 0.77 (95% CI: 0.55, 0.89) for CM and 0.87 (95% CI: 0.72, 0.94) for NCM. Short-axis CM and NCM measurements had a strong to very strong correlation between both sequences (Pearson, 0.86-0.98; Spearman, 0.82-0.98). ICC in 3D whole-heart MRI was 0.96 (95% CI: 0.94, 0.99) for CM and 0.98 (95% CI: 0.97, 0.99) for NCM, while ICC in 2D cine MRI was 0.82 (95% CI: 0.63, 0.92) for CM and 0.87 (95% CI: 0.72, 0.94) for NCM. 3D whole-heart MRI demonstrated higher image quality than did 2D cine MRI (P < .001).

CONCLUSION: 3D whole-heart MRI revealed higher image quality, with better structure discrimination and interobserver agreement in LVNC measurements, compared with standard 2D cine images.Keywords: MR Imaging, Cardiac, Cardiovascular Magnetic Resonance, Left Ventricular Noncompaction, Free-breathing Imaging Technique Supplemental material is available for this article. © RSNA, 2022See also the commentary by Jensen and Petersen in this issue.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Polacin, Károlyi, Wilzeck, et al. Three-dimensional Whole-Heart Cardiac MRI Sequence for Measuring Trabeculation in Left Ventricular Noncompaction. Radiol Cardiothorac Imaging. 2022. PMID: 36601458. doi:10.1148/ryct.220109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。