文献速递甲状腺与浅表头颈US

基于机器学习与预设临床影像特征的甲状腺结节细粒度风险分层系统开发

Development of a machine learning-based fine-grained risk stratification system for thyroid nodules using predefined clinicoradiological features.
PubMed 文献 · Eur Radiol · 2023-01-04

最佳模型在外部验证中AUROC达0.914,敏感度83.2%、特异度89.2%,其AUROC和特异度显著高于TIRADS,敏感度相似。

要点

  • 机器学习模型基于预设超声特征可对甲状腺结节进行恶性风险分层,外部验证AUROC 0.914。
  • 模型特异度(89.2%)显著高于TIRADS(61.3-80.8%),敏感度与TIRADS相似。
  • 该模型有助于提高甲状腺结节恶性风险分层的特异性,辅助个性化管理。

局限性

  • 外部验证仅来自一家三级医院,样本量454个结节,需更多中心验证。
  • 研究为回顾性设计,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We constructed and validated a machine learning-based malignancy risk estimation model using predefined clinicoradiological features, and evaluated its clinical utility for the management of thyroid nodules.

METHODS: In total, 5708 benign (n = 4597) and malignant (n = 1111) thyroid nodules were collected from 5081 consecutive patients treated in 26 institutions. Seventeen experienced radiologists evaluated nodule characteristics on ultrasonographic images. Eight predictive models were used to stratify the thyroid nodules according to malignancy risk; model performance was assessed via nested 10-fold cross-validation. The best-performing algorithm was externally validated using data for 454 thyroid nodules from a tertiary hospital, then compared to the Thyroid Imaging Reporting and Data System (TIRADS)-based interpretations of radiologists (American College of Radiology, European and Korean TIRADS, and AACE/ACE/AME guidelines).

RESULTS: The area under the receiver operating characteristic (AUROC) curves of the algorithms ranged from 0.773 to 0.862. The sensitivities, specificities, positive predictive values, and negative predictive values of the best-performing models were 74.1-76.6%, 80.9-83.4%, 49.2-51.9%, and 93.0-93.5%, respectively. For the external validation set, the ElasticNet values were 83.2%, 89.2%, 81.8%, and 90.1%, respectively. The corresponding TIRADS values were 66.5-85.0%, 61.3-80.8%, 45.9-72.1%, and 81.5-90.3%, respectively. The new model exhibited a significantly higher AUROC and specificity than did the TIRADS risk stratification, although its sensitivity was similar.

CONCLUSION: We developed a reliable machine learning-based predictive model that demonstrated enhanced specificity when stratifying thyroid nodules according to malignancy risk. This system will contribute to improved personalized management of thyroid nodules.

KEY POINTS: • The area under the receiver operating characteristic (AUROC) curve, sensitivity, and specificity of our model were 0.914, 83.2%, and 89.2%, respectively (derived using the validation dataset). • Compared to the TIRADS values, the AUROC and specificity are significantly higher, while the sensitivity is similar. • An interactive version of our AI algorithm is at http://tirads.cdss.co.kr .

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ha, Lee, Lee, et al. Development of a machine learning-based fine-grained risk stratification system for thyroid nodules using predefined clinicoradiological features. Eur Radiol. 2023. PMID: 36600122. doi:10.1007/s00330-022-09376-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。