文献速递妇产影像US

经腹与经阴道超声测量子宫下段厚度检测子宫瘢痕缺陷的比较

Measurement of Lower Uterine Segment Thickness to Detect Uterine Scar Defect: Comparison of Transabdominal and Transvaginal Ultrasound.
PubMed 文献 · J Ultrasound Med · 2023-01-04

本研究纳入747例有剖宫产史孕妇,于孕34-38周测量子宫下段厚度,比较经腹超声、经阴道超声及两者联合(取较薄值)对子宫瘢痕缺陷的检测准确性。结果显示经阴道超声及联合测量优于经腹超声,联合测量AUC最高(88%),以2.3 mm为阈值可预测90%的子宫瘢痕裂开。

要点

  • 经腹超声测量子宫下段厚度大于经阴道超声,联合测量取两者较薄值。
  • 经阴道超声及联合测量对子宫瘢痕裂开的检测准确性优于经腹超声。
  • 以2.3 mm为阈值,联合测量敏感度最高,可预测90%的子宫瘢痕裂开。

关键影像表现/征象

  • 经腹超声测量的子宫下段厚度平均值为3.8±1.6 mm,大于经阴道超声的3.5±1.9 mm和联合测量的3.2±1.5 mm(P < .001)。
  • 经腹超声、经阴道超声和联合测量的AUC分别为78%(95% CI:69%-87%)、85%(95% CI:79%-91%)和88%(95% CI:82%-93%)(均P < .001)。
  • 经腹超声与联合测量的AUC差异无统计学意义(P = .057)。

诊断标准与关键数值

  • 以子宫下段厚度2.3 mm为阈值,经腹超声预测了20例子宫瘢痕裂开中的9例(45%),经阴道超声预测17例(85%),联合测量预测18例(90%)(P < .01)。

临床应用与阅片要点

  • 对于有剖宫产史孕妇,建议联合经腹和经阴道超声测量子宫下段厚度,并取较薄值以提高瘢痕缺陷检出率。
  • 经腹超声测量值可能高估子宫下段厚度,单独使用可能漏诊瘢痕缺陷。

局限性

  • 本研究仅纳入再次剖宫产前未临产者,结果外推需谨慎。
  • 样本来自单中心,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Lower uterine segment (LUS) thickness measurement using transabdominal ultrasound (TA-US), transvaginal ultrasound (TV-US), or the combination of both methods can detect scar defect in women with prior cesarean. We aimed to compare the sensitivity of three approaches.

METHODS: Women with prior cesarean underwent LUS thickness measurement at 34-38 weeks' gestation. Among those who underwent repeat cesarean before labor, we compared the accuracy of TA-US, TV-US, and the thinner of the two measurements (the "combined measurement") for uterine scar dehiscence using the area under the curve (AUC) of receiver operating curves with their 95% confidence intervals (CI). We calculated the sensitivity and specificity of the three approaches using a cut-off of 2.3 mm based on prior literature.

RESULTS: We included 747 participants. The mean LUS thickness was greater with TA-US (3.8 ± 1.6 mm) compared with TV-US (3.5 ± 1.9 mm) or the combined measurement (3.2 ± 1.5 mm; P < .001). The AUC was 78% (95% CI: 69%-87%), 85% (95% CI: 79%-91%), and 88% (95% CI: 82%-93%), respectively (all with P < .001). The AUC difference between TA-US and the combined measurement was not significant (P = .057). A LUS below 2.3 mm would have predicted 9 (45%) of the 20 cases of uterine scar dehiscence using TA-US, 17 (85%) using TV-US, and 18 (90%) using the combined measurement (P < .01).

CONCLUSION: The choice of ultrasound approach influences the measurement of the LUS thickness. The combination of the TA-US and TV-US seems to be superior for the detection of uterine dehiscence.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Marchant, Lessard, Bergeron, et al. Measurement of Lower Uterine Segment Thickness to Detect Uterine Scar Defect: Comparison of Transabdominal and Transvaginal Ultrasound. J Ultrasound Med. 2023. PMID: 36598096. doi:10.1002/jum.16161

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。