文献速递心血管US

PARTNER试验中球囊扩张式经导管心脏瓣膜基于血流的分类的临床与超声心动图特征

Clinical and Echocardiographic Characteristics of Flow-Based Classification Following Balloon-Expandable Transcatheter Heart Valve in PARTNER Trials.
PubMed 文献 · JACC Cardiovasc Imaging · 2022-08-17

基于PARTNER 1/2/3试验中4991例重度主动脉瓣狭窄患者,按基线及术后30天每搏输出量指数(SVI)分为低流量(SVI<35 mL/m2)与正常流量(SVI≥35 mL/m2)组,比较球囊扩张式经导管心脏瓣膜(THV)的超声血流动力学。低流量患者术后有效瓣口面积、平均压降及多普勒速度指数均显著更低,且计算出的严重假体-患者不匹配发生率更高,提示低流量状态下可能出现假性PPM。

要点

  • 评估TAVR术后THV功能时,应结合基线及随访SVI,低流量者血流动力学指标普遍偏低。
  • 低流量患者计算出的严重PPM发生率更高,需警惕低流量导致的假性PPM。
  • 术后SVI由低转为正常者仅17.3%,由正常转为低者12.3%,血流状态可动态变化。

局限性

  • 原文未明确报告研究设计的具体类型(如回顾性分析),仅提及来自随机试验队列。
  • 样本来自随机试验,可能不能完全代表真实世界人群。
  • 仅评估球囊扩张式THV,结论不能外推至其他类型瓣膜。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Current expected normal echocardiographic measures of transcatheter heart valve (THV) function were derived from pooled cohorts of the randomized trials; however, THV function by flow state before or following transcatheter aortic valve replacement (TAVR) has not been previously reported.

OBJECTIVES: This study sought to assess the expected normal echocardiographic hemodynamics for the balloon-expandable THV grouped by stroke volume index (SVI).

METHODS: Patients with severe aortic stenosis enrolled in PARTNER (Placement of Aortic Transcatheter Valves) 1 (high/extreme surgical risk), PARTNER 2 (intermediate surgical risk), or PARTNER 3 (low surgical risk) trials with complete core laboratory echocardiography were included. Patients were grouped by low-flow (SVILOW <35 mL/m2) and normal-flow (SVINORMAL ≥35 mL/m2). Mean gradient, effective orifice area (EOA), and Doppler velocity index (DVI) were collected at baseline and at 30 days post-TAVR. Prosthesis-patient mismatch (PPM) was both calculated and predicted from normative data, using defined criteria.

RESULTS: In the entire population (N = 4,991), mean age was 81.8 years, 58% of patients were male, and 42% had low flow. Compared with patients with baseline SVINORMAL, those with SVILOW were more likely to be male; have more comorbidities; and lower left ventricular ejection fraction, mean gradient, and EOA. Post-TAVR, SVILOW increased to SVINORMAL in 17.3% and SVINORMAL decreased to SVILOW in 12.3% of patients. Using baseline SVI, follow-up EOA, mean gradient, and DVI for patients with SVILOW tended to be lower than for patients with SVINORMAL. Using the post-TAVR SVI, follow-up EOA, mean gradient, and DVI were significantly lower for patients with SVILOW than for those with SVINORMAL (P < 0.001 for all). The incidence of calculated, but not predicted, severe PPM was higher in patients with low flow than it was in patients with normal flow, suggesting pseudo-PPM in the presence of low flow.

CONCLUSIONS: This study demonstrates that flow affects THV hemodynamics and both baseline and follow-up SVI should be considered when predicting THV hemodynamics prior to TAVR, as well as assessing valve function following valve implantation.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Akinmolayemi, Ozdemir, Pibarot, et al. Clinical and Echocardiographic Characteristics of Flow-Based Classification Following Balloon-Expandable Transcatheter Heart Valve in PARTNER Trials. JACC Cardiovasc Imaging. 2022. PMID: 36599555. doi:10.1016/j.jcmg.2022.05.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。