文献速递儿科影像介入DSA

儿童介入放射学中血管与肠造口通路操作的本地参考剂量和可达到剂量水平

Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology.
PubMed 文献 · Pediatr Radiol · 2023-01-03

该回顾性研究基于四级儿童医院2年内3165例血管和肠造口通路操作,按五个体重组建立了常见操作的可达到剂量(第50百分位)和参考剂量(第75百分位)水平及置信区间。研究为儿童介入操作提供了剂量学参考,有助于评估相对辐射风险并改善与介入医师、医护人员、家长和患者的沟通。

要点

  • 儿童介入操作应按体重分组建立本地剂量参考水平。
  • 可达到剂量取第50百分位,参考剂量取第75百分位。
  • 常见操作包括PICC、输液港、中心静脉导管、胃造瘘和胃空肠造瘘管置入及维护。

局限性

  • 回顾性研究设计
  • 单中心研究

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Knowledge of radiation quantities delivered in routine practice is an essential responsibility of a pediatric interventional radiology department.

OBJECTIVE: To review radiation indices in frequently performed vascular and enterostomy access procedures at a quaternary pediatric hospital to formulate dosimetric reference levels and achievable levels.

MATERIALS AND METHODS: A retrospective review of patient demographics, procedure information and quantitative dose metrics over a 2-year period was performed. Dosimetric details for common procedures (central line insertions, gastrostomy/gastrojejunostomy insertions and maintenance) were evaluated, correlated with demographic data and stratified across five weight groups (0-5 kg, 5-15 kg, 15-30 kg, 30-50 kg, 50-80 kg). Achievable (50th percentile) and reference (75th percentile) levels with confidence intervals were established for each procedure.

RESULTS: Within the evaluation period, 3,165 studies satisfied the inclusion criteria. Five were classified as device insertions (peripherally inserted central catheter, n=1,145; port-a-catheter, n=321; central venous line, n=285; gastrostomy-tube [G-tube], n=262, and gastrojejunostomy-tube [GJ-tube], n=66), and two were classified as maintenance procedures (G-tube, n=358, and GJ-tube, n=728, checks, exchanges and reinsertions). Representative reference and achievable levels were calculated for each procedure category and weight group.

CONCLUSION: This work highlights the creation of local reference and achievable levels for common pediatric interventional procedures. These data establish a dosimetric reference to understand the quantity of radiation routinely applied, allowing for improved relative radiation risk assessment and enriched communication to interventionalists, health care providers, parents and patients.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Shkumat, Chiramel, Muthusami, et al. Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology. Pediatr Radiol. 2023. PMID: 36595081. doi:10.1007/s00247-022-05562-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。