低剂量光子计数探测器胸部CT在儿童囊性纤维化中可靠显示Brody II评分影像表现
三位儿科放射科医师采用Brody II评分评估,结果显示图像质量可诊断,Brody II评分组内相关系数为0.61,支气管扩张、支气管周围增厚、肺实质模糊和空气潴留的评估信度中等至良好,但黏液栓塞信度差。
要点
- 低剂量PCD-CT可在接近胸片辐射剂量下获得可诊断的儿童CF胸部图像。
- Brody II评分各征象中,空气潴留信度最高(0.70),黏液栓塞信度差(0.09)。
- 日常阅片需注意黏液栓塞评估的可重复性较低。
关键影像表现/征象
- 所有三位阅片者均评价肺窗空间分辨率和噪声为可解读。
- 平均Brody II评分为12.5(范围4-19)。
诊断标准与关键数值
- 平均容积CT剂量指数(CTDIvol)为每次扫描0.07 ± 0.03 mGy。
- 总检查平均有效剂量为0.12 ± 0.04 mSv。
- Brody II评分组内相关系数(ICC)为0.61(95% CI=0.27, 0.84),信度中等。
- 各征象信度:支气管扩张0.52,支气管周围增厚0.55,肺实质模糊存在0.62,空气潴留0.70,黏液栓塞0.09。
局限性
- 黏液栓塞信度差,可能影响评分可靠性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The Brody II score uses chest CT to guide therapeutic changes in children with cystic fibrosis; however, patients and providers are often reticent to undergo chest CT given concerns about radiation.
OBJECTIVE: We sought to determine the ability of a reduced-dose photon-counting detector (PCD) chest CT protocol to reproducibly display pulmonary disease severity using the Brody II score for children with cystic fibrosis (CF) scanned at radiation doses similar to those of a chest radiograph.
MATERIALS AND METHODS: Pediatric patients with CF underwent non-contrast reduced-dose chest PCD-CT. Volumetric inspiratory and expiratory scans were obtained without sedation or anesthesia. Three pediatric radiologists with Certificates of Added Qualification scored each scan on an ordinal scale and assigned a Brody II score to grade bronchiectasis, peribronchial thickening, parenchymal opacity, air trapping and mucus plugging. We report image-quality metrics using descriptive statistics. To calculate inter-rater agreement for Brody II scoring, we used the Krippendorff alpha and intraclass correlation coefficient (ICC).
RESULTS: Fifteen children with CF underwent reduced-dose PCD chest CT in both inspiration and expiration (mean age 8.9 years, range, 2.5-17.5 years; 4 girls). Mean volumetric CT dose index (CTDIvol) was 0.07 ± 0.03 mGy per scan. Mean effective dose was 0.12 ± 0.04 mSv for the total examination. All three readers graded spatial resolution and noise as interpretable on lung windows. The average Brody II score was 12.5 (range 4-19), with moderate inter-reader reliability (ICC of 0.61 [95% CI=0.27, 0.84]). Inter-rater reliability was moderate to substantial for bronchiectasis (0.52), peribronchial thickening (0.55), presence of opacity (0.62) and air trapping (0.70) and poor for mucus plugging (0.09).
CONCLUSION: Reduced-dose PCD-CT permits diagnostic image quality and reproducible identification of Brody II scoring imaging findings at radiation doses similar to those for chest radiography.
引用
- Horst, Hull, Thacker, et al. Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs. Pediatr Radiol. 2023. PMID: 36596868. doi:10.1007/s00247-022-05574-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。