文献速递神经外周血管CT

双能CT血管成像参数评估血栓成分的价值

The Value of Dual-Energy Computed Tomography Angiography-Derived Parameters in the Evaluation of Clot Composition.
PubMed 文献 · Acad Radiol · 2022-12-30

本研究纳入88例急性缺血性卒中患者,术前DE-CTA测量血栓参数并与取出血栓成分对比。54例(61.36%)为红细胞优势型,其VNC值较高而IC、λHU、Zeff值较低。IC图像CT密度诊断红细胞优势血栓AUC达0.94,与红细胞比例相关性最强(r=-0.64)。

要点

  • IC图像CT密度是评估血栓红细胞成分的最佳DE-CTA参数
  • 红细胞优势血栓VNC值更高,IC、λHU、Zeff值更低
  • DE-CTA参数有助于个体化取栓策略制定

关键影像表现/征象

  • 红细胞优势血栓VNC值显著高于F/P优势血栓(p<0.05)。
  • 红细胞优势血栓IC、λHU、Zeff值显著低于F/P优势血栓(p<0.05)。

诊断标准与关键数值

  • IC图像CT密度诊断红细胞优势血栓AUC 0.94,敏感度77.78%,特异度100.00%。
  • IC图像CT密度与红细胞比例负相关(r=-0.64,p<0.001),与F/P正相关(r=0.65,p<0.001)。

临床应用与阅片要点

  • 阅片时可利用DE-CTA的IC图像CT密度无创评估血栓成分。
  • 红细胞优势血栓可能对取栓反应不同,参数可辅助制定个体化策略。

局限性

  • 回顾性设计,样本量有限(88例),单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to assess the value of dual-energy computed tomography angiography (DE-CTA) derived parameters as a quantitative biomarker of thrombus composition in acute ischemic stroke (AIS).

METHODS: AIS patients who underwent DE-CTA before thrombectomy between August 2016 and September 2022 were included in this study. We assessed the relative proportion of red blood cells (RBCs) and the fibrin/platelet ratio (F/P) of the retrieved clots and categorized the clots as RBC-dominant (RBCs > F/P) or F/P-dominant (F/P > RBCs). The thrombus based parameters were measured on polyenergetic images (PEI), virtual monoenergetic (VM), virtual non-contrast (VNC), iodine concentration (IC), and effective atomic number (Zeff) images respectively, and the slope of the spectral Hounsfield unit curve (λHU) was calculated. These parameters were compared in the DE-CTA images of RBC- and F/P-dominant thrombi. The diagnostic performance of the parameters was analyzed using the ROC curve. Correlations between thrombus composition and DE-CTA-derived parameters were assessed.

RESULTS: The retrieved clots in 54 of 88 patients (61.36%) were RBC-dominant. The RBC-dominant thrombi showed significantly higher VNC values and lower IC, λHU, and Zeff values than the F/P-dominant thrombi (p < 0.05). The CT density measured on IC images showed the largest AUC value (AUC, 0.94; sensitivity, 77.78%; specificity, 100.00%). The Spearman rank-order correlation coefficient values showed that CT density measured on IC images of the thrombus showed the strongest association with the proportion of RBCs (r = -0.64, p < 0.001) and F/P (r = 0.65, p < 0.001).

CONCLUSIONS: DE-CTA-derived parameters, especially the CT density measured on IC images, could be associated with thrombus composition and allow for personalized thrombectomy strategies.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang, Gu, Li, et al. The Value of Dual-Energy Computed Tomography Angiography-Derived Parameters in the Evaluation of Clot Composition. Acad Radiol. 2022. PMID: 36587997. doi:10.1016/j.acra.2022.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。