减影技术提高严重钙化患者冠状动脉CT血管造影识别中重度狭窄的准确性:一项多中心研究
该多中心前瞻性研究纳入180例有冠状动脉钙化斑块并接受冠状动脉CT血管造影和侵入性冠状动脉造影的患者,按Agatston评分分为三组。以ICA为参考标准,比较常规CCTA与减影CCTA的诊断准确性。结果显示,在Agatston评分≥400的患者中,减影技术对识别≥50%和≥70%冠状动脉狭窄的准确性均显著提高,而在低至中度钙化组未见改善。
要点
- 对于Agatston评分≥400的患者,减影CCTA可提高识别≥50%和≥70%狭窄的准确性。
- 减影CCTA在低至中度钙化(Agatston评分<400)患者中未见诊断准确性改善。
- 临床实践中,对严重钙化患者可考虑应用减影技术辅助评估冠状动脉狭窄。
诊断标准与关键数值
- 识别≥70%狭窄时,B组减影CCTA的AUC为0.92,常规CCTA为0.80(p=0.001);C组减影CCTA的AUC为0.84,常规CCTA为0.75(p=0.001)。
- 识别≥50%狭窄时,B组减影CCTA的AUC为0.92,常规CCTA为0.81(p<0.001);C组减影CCTA的AUC为0.88,常规CCTA为0.77(p<0.001)。
- A组(Agatston评分<400)减影CCTA与常规CCTA的诊断准确性无显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To investigate the diagnostic accuracy of subtraction coronary computed tomographic angiography (CCTAsub) in identifying ≥ 50% and ≥ 70% coronary stenosis in patients with different degrees of calcification.
MATERIALS AND METHODS: In this study, 180 patients with coronary calcified plaques who underwent both coronary CT angiography and invasive coronary angiography (ICA) were prospectively enrolled at five centers. Patients were divided into three groups according to the Agatston score: group A (low to moderate, < 400), group B (high, 400-999), and group C (very high, ≥ 1000). Diagnostic accuracies estimated by area under the receiver operating characteristic curve (AUC) were compared between conventional CCTA (CCTAcon) and CCTAsub, with ICA as a reference standard.
RESULTS: There were 86 patients in group A, 44 in group B, and 50 in group C. In identifying ≥ 70% coronary stenosis, subtraction improved the diagnostic accuracies on a per-segment basis in group B (AUC: 0.80 vs 0.92, p = 0.001) and group C (AUC: 0.75 vs 0.84, p = 0.001) after subtraction. When identifying ≥ 50% coronary stenosis, the per-segment AUC of CCTAsub in group B and C were significantly higher than that in CCTAcon (group B: 0.81 vs 0.92, p < 0.001; group C: 0.77 vs 0.88, p < 0.001). However, no improvement was observed in group A.
CONCLUSION: Subtraction achieved better diagnostic accuracy in patients with Agatston score ≥ 400, both in identifying ≥ 50% and ≥ 70% coronary stenosis, which was instructive for the application of subtraction in clinical practice.
引用
- Qiao, Li, Yang, et al. Subtraction Improves the Accuracy of Coronary CT Angiography in Patients with Severe Calcifications in Identifying Moderate and Severe Stenosis: A Multicenter Study. Acad Radiol. 2022. PMID: 36586762. doi:10.1016/j.acra.2022.11.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。