射血分数降低型心力衰竭中的涡流碎片化:一项前瞻性向量血流成像研究
该前瞻性研究纳入20例射血分数降低型心力衰竭(HFrEF)患者和20例年龄性别匹配的正常对照,采用超声向量血流成像比较心内涡流特征。结果显示HFrEF患者涡流面积指数更小、涡流数量更多(收缩期和舒张期均碎片化)、舒张期能量损耗更高,且E涡和A涡更靠近心尖、S涡更弱,涡流碎片化程度与能量效率降低相关。
要点
- HFrEF患者心内涡流更碎片化,表现为单帧最大涡流数(MNV)在收缩期和舒张期均升高。
- HFrEF患者舒张期能量损耗增高,且涡流碎片化程度与能量效率降低相关。
- HFrEF患者E涡和A涡位置更靠心尖,收缩期S涡强度减弱。
关键影像表现/征象
- HFrEF患者涡流面积指数(以左室舒张末内径标化)更小(p < 0.0001),涡流大小不成比例。
- HFrEF患者单帧最大涡流数(MNV)在收缩期(p = 0.030)和舒张期(p < 0.0001)均更高,提示涡流更碎片化。
- HFrEF患者舒张期能量损耗更高(p = 0.001)。
- HFrEF患者E涡(p = 0.002)和A涡(p < 0.0001)位置更靠心尖,S涡强度更弱(p = 0.033)。
临床应用与阅片要点
- 向量血流成像可定量评估心内涡流的面积、循环强度、位置和碎片化程度,辅助评估HFrEF患者心功能。
- 阅片时关注舒张期涡流碎片化(MNV增高)和能量损耗增高,可能提示能量效率降低。
- 注意涡流面积需以左室舒张末内径标化后比较。
局限性
- 样本量较小(每组20例),结果需更大样本验证。
- 单中心前瞻性研究,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Heart failure with reduced ejection fraction (HFrEF) is associated with structural and functional left ventricular changes. We compared intracardiac vortices between patients with HFrEF and normal participants using echocardiographic vector flow mapping, a novel intracardiac vortex analysis technology.
METHODS: Transthoracic echocardiography was performed on 20 patients with HFrEF (age: 61 ± 15 y, 15 men) and 20 normal participants (age: 59 ± 12 y, 12 men) age- and sex-balanced at the cohort level. Systolic and diastolic energy loss, area (indexed by left ventricular end-diastolic diameter), circulation (reflects vortex strength) and relative positions of the largest vortex during systole (S-vortex), early (E-vortex) and late (A-vortex) diastole and maximal number of vortices in a single frame (MNV) were assessed.
DISCUSSION: Patients with HFrEF had disproportionately sized vortices with smaller indexed vortex areas (p < 0.0001), and more fragmented vortices with higher MNV during both systole (p = 0.030) and diastole (p < 0.0001). These accompanied higher diastolic energy loss (p = 0.001). Additionally, the E-vortex (p = 0.002) and A-vortex (p < 0.0001) were more apically positioned, and the S-vortex was weaker (p = 0.033) in patients with HFrEF. More severe fragmentation (higher MNV) correlated with worse energy efficiency (higher energy loss).
CONCLUSION: Patients with HFrEF had more fragmented intracardiac vortices and lower energy efficiency predominantly during diastole.
引用
- Chan, Lau, Fan, et al. Fragmented Vortex in Heart Failure With Reduced Ejection Fraction: A Prospective Vector Flow Mapping Study. Ultrasound Med Biol. 2022. PMID: 36581516. doi:10.1016/j.ultrasmedbio.2022.12.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。