文献速递骨肌神经CT

双能CT无体模骨密度与急性脊柱功能不全骨折的相关性

Association of Phantomless Dual-Energy CT-based Volumetric Bone Mineral Density with the Prevalence of Acute Insufficiency Fractures of the Spine.
PubMed 文献 · Acad Radiol · 2022-12-26

回顾性分析160例疑似功能不全骨折患者的第三代双源双能CT数据,采用无体模材料分解法测量L1骨密度。结果发现,双能CT骨密度阈值120.40 mg/cm³区分有无骨折的特异度90.1%、敏感度59.32%,AUC为0.82,较低骨密度与骨折风险增加相关(OR 0.93)。该算法可用于常规CT患者的无体模骨折风险分层。

要点

  • 双能CT无体模骨密度测量可辅助识别胸腰椎急性功能不全骨折高风险患者。
  • L1骨密度阈值120.40 mg/cm³区分骨折的AUC为0.82,特异度90.1%。
  • 无骨折患者骨密度均未低于85 mg/cm³,可作为排除骨折的参考下限。

局限性

  • 回顾性单中心设计,可能存在选择偏倚。
  • 仅分析L1骨密度,未评估其他椎体或部位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the bone mineral density (BMD) of the lumbar spine derived from dual-energy CT (DECT)-based volumetric material decomposition and its association with acute insufficiency fractures of the thoracolumbar spine.

MATERIALS AND METHODS: L1 of 160 patients (77 men, 83 women; mean age 64.3 years, range, 22-94 years) who underwent third-generation dual-source DECT between January 2016 and December 2021 due to suspected insufficiency fractures was retrospectively analyzed. All depicted vertebrae were examined for signs of recent fractures. A dedicated DECT postprocessing software using material decomposition was applied for phantomless BMD assessment. Receiver-operating characteristic (ROC) analysis identified optimal BMD thresholds. Associations of BMD, sex, and age with the occurrence of insufficiency fractures were examined with logistic regression models.

RESULTS: A DECT-derived BMD threshold of 120.40 mg/cm³ yielded 90.1% specificity and 59.32% sensitivity to differentiate patients with at least one insufficiency fracture from patients without fracture. No patient without fracture had a DECT-derived BMD below 85 mg/cm3. Lower DECT-derived bone mineral density was associated with an increased risk of insufficiency fractures (Odds ratio of 0.93, 95% CI, 0.91-0.96, p < 0.001). Overall ROC-derived AUC was 0.82 (p < 0.0001) for the differentiation of patients that sustained an insufficiency fracture from the control group.

CONCLUSION: Dual-Energy CT-based BMD assessment can accurately differentiate patients with acute insufficiency fractures of the thoracolumbar spine from patients without fracture. This algorithm can be used for phantomless risk stratification of patients undergoing routine CT to sustain insufficiency fractures of the thoracolumbar spine The identified cut-off value of 120.4 mg/cm³ is in line with current American College of Radiology (ACR) recommendations to differentiate healthy individuals from those with reduced bone mineral density.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gruenewald, Koch, Yel, et al. Association of Phantomless Dual-Energy CT-based Volumetric Bone Mineral Density with the Prevalence of Acute Insufficiency Fractures of the Spine. Acad Radiol. 2022. PMID: 36577605. doi:10.1016/j.acra.2022.11.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。