酰胺质子转移成像评估膀胱癌组织病理学特征:与扩散加权成像的对比研究
结果显示,高级别肿瘤及肌层浸润性膀胱癌(MIBC)的MTRasym值显著更高,APT预测肿瘤侵袭性的诊断性能优于DWI,且APT联合DWI可显著提高鉴别MIBC与非肌层浸润性膀胱癌(NMIBC)的准确度。
要点
- MTRasym在高档别膀胱肿瘤及MIBC中显著升高,可用于无创评估肿瘤分级与侵袭性。
- APT预测MIBC的AUC(0.973)显著优于ADC(0.771),联合DWI可进一步提升准确度。
- 阅片时关注APT不对称磁化转移率(MTRasym)的定量测量,辅助DWI进行膀胱癌术前分级。
关键影像表现/征象
- 高级别膀胱肿瘤的MTRasym值显著高于低级别肿瘤(1.61% [0.76%] vs 1.12 ± 0.3%,P = 0.000)。
- MIBC的MTRasym值显著高于NMIBC(2.53 ± 0.67% vs 1.38% [0.35%],P = 0.000)。
诊断标准与关键数值
- MTRasym定义为3.5 ppm处的磁化转移不对称率。
- MTRasym鉴别MIBC与NMIBC的AUC为0.973,显著大于ADC的AUC 0.771(P = 0.016)。
- APT联合DWI鉴别MIBC与NMIBC的诊断准确度为0.985,显著高于单独DWI的0.876(P = 0.013)。
临床应用与阅片要点
- 在膀胱癌术前MRI评估中,可结合APT定量参数MTRasym辅助DWI判断肿瘤分级及肌层浸润情况。
- MTRasym值越高提示肿瘤级别越高、侵袭性越强,需警惕肌层浸润可能。
局限性
- 单中心研究设计,结论需多中心大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the ability of amide proton transfer (APT) imaging, in comparison with diffusion-weighted imaging (DWI), to differentiate low-grade from high-grade bladder tumors and predict the aggressiveness of bladder cancer (BCa).
METHODS: Forty-eight patients diagnosed with BCa confirmed by histopathological findings who underwent magnetic resonance (MR) imaging, including APT imaging and DWI (b = 0, 1000 sec/mm2), were enrolled in this study. The asymmetric magnetization transfer ratio (MTRasym) was defined as the magnetization transfer asymmetry at 3.5 ppm. MTRasym and apparent diffusion coefficients (ADCs) were compared between the low- and high-grade groups and between non-muscle-invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC) in terms of the areas under the receiver operating characteristic curves (AUCs).
RESULTS: The MTRasym values were significantly higher in patients with high-grade bladder tumors than in those with low-grade tumors (1.61 % [0.76 %], 1.12 ± 0.3 %; P = 0.000) and in MIBC than in NMIBC (2.53 ± 0.67 %, 1.38 % [0.35 %]; P = 0.000). The AUCs of MTRasym were significantly larger than those of ADC for differentiating MIBC from NMIBC (0.973, 0.771; P = 0.016). Adding APT imaging to DWI significantly improved the diagnostic accuracy for differentiating MIBC from NMIBC versus DWI alone (0.985, 0.876; P = 0.013).
CONCLUSIONS: APT imaging can predict tumor grade and aggressiveness in BCa. The diagnostic performance of APT imaging in predicting tumor aggressiveness was better than that of DWI, and adding APT imaging to DWI significantly improved the diagnostic accuracy of predicting tumor aggressiveness versus DWI alone.
引用
- Wang, Xiang, Wu, et al. Evaluation of amide proton transfer imaging for bladder cancer histopathologic features: A comparative study with diffusion- weighted imaging. Eur J Radiol. 2022. PMID: 36574743. doi:10.1016/j.ejrad.2022.110664
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。