PubMed 文献 · Ultrasound Med Biol · 2022-12-24

剪切波弹性成像(整体硬度阈值35 kPa)的总体敏感度65.3%、特异度70.2%;应变弹性成像的总体敏感度58.9%、特异度71.8%。分区剪切波阈值(外周带35 kPa、移行带45 kPa)的总体敏感度63.4%、特异度73.0%。剪切波弹性成像敏感度高于应变弹性成像(63.4% vs 58.9%,p=0.038),特异度相当(73.0% vs 71.8%,p=0.547)。

要点

  • 剪切波弹性成像检测前列腺癌的敏感度高于应变弹性成像,特异度两者相当。
  • 剪切波弹性成像采用分区阈值(外周带35 kPa、移行带45 kPa)时诊断效能更优。
  • 两种方法对较大病灶的敏感度更高,但应变弹性成像对包膜附近大直径Gleason评分5病灶敏感度下降。
英文原文(摘要)· 点击展开

The aim of the study was to compare strain elastography with shear wave elastography in prostate cancer detection by comparing data gained during elastography with histological analysis after prostatectomy. Thirty patients with prostate cancer qualified for radical prostatectomy were enrolled into the study. All patients underwent transrectal strain elastography and shear wave elastography during pre-surgical evaluation. In each prostate, 36 regions were evaluated separately whether there was a suspicious prostate cancer lesion or not. Subsequently, the same regions were analyzed during histological analysis of the resected gland. Strain elastography and shear wave elastography (overall stiffness cutoff value = 35 kPa) in our study were characterized by overall sensitivities of 58.9% and 65.3% and specificities of 71.8% and 70.2%, respectively. Cutoff values specific to the zones in the shear wave elastography examination (peripheral zone: 35 kPa, transitional zone: 45 kPa) were characterized by an overall prostate cancer detection sensitivity and specificity of 63.4% and 73% respectively. Shear wave elastography examination revealed a higher sensitivity versus strain elastography, 63.4% versus 58.9% (p = 0.038, p < 0.05), and comparable specificity, 73.0% versus 71.8% (p = 0.547, p > 0.05), respectively. Sensitivity in prostate cancer detection for both methods is higher for larger lesions (except Gleason score 5 massive lesions in strain elastography). Controversially we observed a decrease in sensitivity for strain elastography in the detection of lesions with a large diameter and a Gleason score of 5 near the prostate capsule. Overall sensitivity in the diagnosis of prostate cancer is more significant for shear wave elastography versus strain elastography.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Tyloch, Tyloch, Adamowicz, et al. Comparison of Strain and Shear Wave Elastography in Prostate Cancer Detection. Ultrasound Med Biol. 2022. PMID: 36572589. doi:10.1016/j.ultrasmedbio.2022.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。