指南与共识儿科影像神经技术与安全MR

ACR适用标准与EURO-2000指南对儿童MRI转诊场景覆盖有限

American College of Radiology (ACR) Appropriateness Criteria and EURO-2000 Guidelines Offer Limited Guidance for MRI Imaging of Pediatric Patients.
指南 / 共识 · Acad Radiol · 2022-12-24

该回顾性多中心研究将比利时三家医院1000例连续儿童MRI申请中的2932个临床场景分别匹配EURO-2000指南与ACR适用标准,发现两指南仅覆盖约三分之一场景(37.99% vs 36.37%,P=0.12),但对已覆盖场景的转诊合规率均超过94%。头颈、胸部及腹盆部是未来决策支持工具需重点关注的解剖区域。

要点

  • 两指南仅覆盖约三分之一儿童MRI临床场景,约三分之二场景无指南可依。
  • EURO-2000对头部和脊柱覆盖更优,ACR对腹部、盆腔和骨肌覆盖更广。
  • 对已覆盖场景,两指南的转诊合规率在各中心均超过94%。

核心结论

  • EURO-2000指南与ACR适用标准均未覆盖约三分之二的儿童MRI临床场景。
  • 两指南总体覆盖率无统计学差异,但覆盖优势的解剖区域不同。
  • 对已覆盖场景,转诊医师对两指南的合规率均超过94%。

研究设计与样本

  • 回顾性多中心研究,纳入比利时一所大学儿童医院和两所综合大学医院。
  • 分析2022年1月前最后1000例连续儿童(0-16岁)MRI申请,排除不完整或缺失申请后纳入2932/3000例。
  • 将临床场景分别与EURO-2000指南和ACR适用标准匹配,独立评估覆盖数与转诊合理性。
  • 汇总三中心数据后按中心、解剖部位和转诊医师专科分层分析。
  • 采用McNemar检验比较配对比例,χ2检验比较非配对比例。

诊断标准与关键数值

  • EURO-2000指南覆盖1229/2932个临床场景(37.99%)。
  • ACR适用标准覆盖1081/2932个临床场景(36.37%)。
  • 两指南覆盖率比较McNemar检验P=0.12。
  • EURO-2000对头部和脊柱覆盖优于ACR(P<0.05)。
  • ACR对腹部、盆腔和骨肌系统覆盖优于EURO-2000(P<0.0001)。

临床应用与阅片要点

  • 儿童MRI转诊合理性评估可参考两指南已覆盖场景,但约三分之二场景需临床判断。
  • 头部和脊柱MRI转诊可优先参照EURO-2000指南。
  • 腹部、盆腔和骨肌MRI转诊可优先参照ACR适用标准。
  • 头颈、胸部和腹盆部是现有指南覆盖薄弱区,报告时需注意转诊合理性缺乏指南依据。

局限性

  • 回顾性研究设计。
  • 仅纳入比利时三家医院,外推性受限。
  • 原文未报告其他明显局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aims to evaluate the clinical scenarios addressed by the EURO-2000 guidelines and the ACR appropriateness criteria for referring children to MRI and assessing the referring physician compliance with both guidelines.

METHODS: In January 2022, clinical scenarios reported in the last 1000 consecutive MRI requests for children (0-16 years) in one university children's hospital and two general university hospitals in Belgium, Europe, were retrospectively matched to the EURO-2000 guidelines and ACR appropriateness criteria. The number of clinical scenarios addressed and the justification for MRI referral were independently assessed for both guidelines. Pooled data from the three centers were evaluated and then analyzed by center, body area and prescriber using McNemar's test for paired proportions and χ2-tests unpaired proportions.

RESULTS: After excluding incomplete or missing MRI requests, 2932 of 3000 requests were included in the analysis. Overall, out of 2932 clinical scenarios, 1229 (37.99%) were addressed by EURO-2000 and 1081 (36.37%) were addressed by the ACR appropriateness criteria (McNemar test, p = 0.12). The proportions of clinical scenarios covered by the two guidelines were statistically similar when comparing centers, but varied across body regions (p < 0.001) and referring physician specialty (p between 0.75 and 0.001). EURO-2000 guidelines provided better coverage for head and spine (p < 0.05), while the ACR appropriateness criteria provided broader coverage for abdomen, pelvis, and musculoskeletal system (p < 0.0001). For addressed clinical scenarios, prescriber compliance for both guidelines was excellent with > 94% of justified MRI examinations in all the centers.

CONCLUSIONS: Both the EURO-2000 guidelines and the ACR appropriateness criteria did not address two-thirds of clinical scenarios in children. Head and neck, chest and abdominal-pelvic examinations are the anatomic regions which should receive a specific attention for the future implementation of evidence-based clinical decision support tools for all referring specialists.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Simoni, Kozlowski, Boitsios, et al. American College of Radiology (ACR) Appropriateness Criteria and EURO-2000 Guidelines Offer Limited Guidance for MRI Imaging of Pediatric Patients. Acad Radiol. 2022. PMID: 36572626. doi:10.1016/j.acra.2022.12.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。