全身PET/CT缩短采集时间的呼吸门控成像在可疑恶性肿瘤中的首次应用

Respiratory-gated PET imaging with reduced acquisition time for suspect malignancies: the first experience in application of total-body PET/CT.
PubMed 文献 · Eur Radiol · 2022-12-24

本研究纳入71例可疑恶性肿瘤患者,使用全身PET/CT进行15分钟呼吸记录扫描,比较四种重建图像(Ungated-15、Ungated-5、Gated-15、Gated-6)。共发现390个胸部及上腹部病灶,Gated-15病灶检出率(97.2%)显著高于Ungated-15(93.6%)和Ungated-5(92.3%),但与Gated-6(95.9%)相当。Gated-15较非门控图像病灶SUV、肿瘤/肝比、肿瘤/血池比更高,MTV更小,且门控图像噪声略高但可接受。结论认为全身PET/CT缩短扫描时间的呼吸门控成像优于非门控,可用于临床。

要点

  • 呼吸门控可提高病灶检出率及定量参数准确性,全身PET/CT支持缩短采集时间。
  • Gated-6与Gated-15病灶检出率及定量指标无显著差异,提示6分钟门控采集可行。
  • 门控图像噪声较非门控高,但仍在临床可接受范围。

关键影像表现/征象

  • 共发现390个胸部及上腹部病灶,Gated-15检出率97.2%显著高于Ungated-15的93.6%(p=0.001)和Ungated-5的92.3%(p=0.001),与Gated-6的95.9%无显著差异(p=0.993)。
  • 对131个病灶定量分析显示,Gated-15的标准化摄取值、肿瘤/肝比、肿瘤/血池比显著大于Ungated-15和Ungated-5(均p<0.001),代谢肿瘤体积更小。
  • 上述差异在小病灶及非纵隔/腹膜后部位病灶中更明显,Gated-15与Gated-6间各定量指标无显著差异。
  • 门控图像噪声高于非门控图像,但可接受。

临床应用与阅片要点

  • 在全身PET/CT中可考虑采用缩短采集时间的呼吸门控(如6分钟)替代非门控,以提高胸部及上腹部病灶检出率和定量准确性。
  • 注意门控图像噪声较高,阅片时需结合图像质量评估,避免因噪声误判。

局限性

  • 单中心研究,样本量71例,结论需多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to investigate the performance of respiratory-gating imaging with reduced acquisition time using the total-body positron emission tomography/computed tomography (PET/CT) scanner.

METHODS: Imaging data of 71 patients with suspect malignancies who underwent total-body 2-[18F]-fluoro-2-deoxy-D-glucose PET/CT for 15 min with respiration recorded were analyzed. For each examination, four reconstructions were performed: Ungated-15, using all coincidences; Ungated-5, using data of the first 5 min; Gated-15 using all coincidences but with respiratory gating; and Gated-6 using data of the first 6 min with respiratory gating. Lesions were quantified and image quality was evaluated; both were compared between the four image sets.

RESULTS: A total of 390 lesions were found in the thorax and upper abdomen. Lesion detectability was significantly higher in gated-15 (97.2%) than in ungated-15 (93.6%, p = 0.001) and ungated-5 (92.3%, p = 0.001), but comparable to Gated-6 (95.9%, p = 0.993). A total of 131 lesions were selected for quantitative analyses. Lesions in Gated-15 presented significantly larger standardized uptake values, tumor-to-liver ratio, and tumor-to-blood ratio, but smaller metabolic tumor volume, compared to those in Ungated-15 and Ungated-5 (all p < 0.001). These differences were more obvious in small lesions and in lesions from sites other than mediastinum/retroperitoneum. However, these indices were not significantly different between Gated-15 and Gated-6. Higher, but acceptable, image noise was identified in gated images than in ungated images.

CONCLUSIONS: Respiratory-gating imaging with reduced scanning time using the total-body PET/CT scanner is superior to ungated imaging and can be used in the clinic.

KEY POINTS: • In PET imaging, respiratory gating can improve lesion presentation and detectability but requires longer imaging time. • This single-center study showed that the total-body PET scanner allows respiratory-gated imaging with reduced and clinically acceptable scanning time.

来源:Eur Radiol,查看原文。版权归原作者所有。