文献速递神经儿科影像CT

儿童脑部CT检查的图像质量、器官剂量、有效剂量与癌症风险评估

Evaluation of image quality, organ doses, effective dose, and cancer risk from pediatric brain CT scans.
PubMed 文献 · Eur J Radiol · 2022-12-16

该研究纳入179例12岁以下行非增强脑CT的儿童,按年龄分为≤1、2-5、6-9、10-12岁四组,用ImpactDose程序计算器官剂量和有效剂量,基于BEIR VII报告模型估算辐射暴露诱发癌症死亡风险(REID),并测量噪声、SNR和CNR评估图像质量。结果显示各年龄组中脑部器官剂量最高,平均REID为男性12.34/10万、女性16.77/10万,REID随年龄增长而降低且女性高于男性;灰质SNR、白质SNR和CNR均值分别为11.04、10.5和2.31。结论认为儿童脑CT存在增加的潜在癌症风险,应尽量减少不必要辐射暴露、考虑替代成像方式,并在保持诊断图像质量的前提下优化辐射参数。

要点

  • 儿童脑CT各年龄组中脑部器官剂量最高,应关注辐射剂量优化。
  • 女性儿童REID高于男性,且REID随年龄增长而降低。
  • 在保持诊断质量前提下优化辐射参数,并优先考虑替代成像方式。

局限性

  • 单中心研究,样本量有限(179例)。
  • 仅纳入12岁以下儿童,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The present study was conducted to assess organ doses, effective dose, and image quality, and to estimate the risk of exposure-induced cancer death (REID) in pediatric brain computed tomography examinations.

METHODS: This investigation was performed on 179 pediatric patients (99 men and 80 women) under 12 years old who underwent non-contrast brain CT scans. Patients were classified into four age groups of ≤ 1, 2-5, 6-9, and 10-12 years old. Organ doses and effective doses were calculated using the ImpactDose program. Cancer risk models presented in the BEIR VII report were used to estimate REID values. Image quality assessment in this study was performed by measuring image quality parameters such as noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR).

RESULTS: The highest organ dose in all age groups belonged to the brain. The mean REID values were 12.34 per 100,000 males and 16.77 per 100,000 females. REID values decreased with the increasing age of patients in both genders and were higher for female children than male children. The mean SNR of gray matter, SNR of white matter, and CNR were 11.04, 10.5, and 2.31, respectively.

CONCLUSIONS: According to the results of this study, brain CT scans in children are associated with an increased potential risk of cancer. Therefore, minimizing unnecessary radiation exposure in pediatric patients and using alternative imaging modalities are of particular importance. Moreover, optimizing the radiation parameters while maintaining the diagnostic image quality in children should be considered.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kiani, Chaparian. Evaluation of image quality, organ doses, effective dose, and cancer risk from pediatric brain CT scans. Eur J Radiol. 2022. PMID: 36542932. doi:10.1016/j.ejrad.2022.110657

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。