BI-RADS联合自动乳腺容积扫描与剪切波弹性成像对乳腺病变的诊断价值

The Diagnostic Significance of the BI-RADS Classification Combined With Automated Breast Volume Scanner and Shear Wave Elastography for Breast Lesions.
PubMed 文献 · J Ultrasound Med · 2022-12-19

该研究以病理为金标准,比较BI-RADS、ABVS、SWE及联合方法对乳腺病变的分类诊断效能。结果显示BI-RADS+ABVS+SWE联合应用具有最高敏感度96.91%、特异度94.74%及阴性预测值97.70%,ABVS和SWE可减少BI-RADS的主观性。

要点

  • ABVS上恶性组「回缩征」发生率显著高于良性组,有助鉴别。
  • BI-RADS联合SWE-Max可显著提高敏感度至92.78%和阴性预测值至94.40%。
  • BI-RADS+ABVS+SWE三联联合诊断效能最高,敏感度96.91%、特异度94.74%。

核心结论

  • ABVS与SWE可减少BI-RADS分类的主观性,BI-RADS+ABVS+SWE联合诊断准确率最高。

研究设计与样本

  • 研究论文,以病理为金标准,由两名专科超声医师分别用BI-RADS、BI-RADS+ABVS、BI-RADS+SWE及BI-RADS+ABVS+SWE评估乳腺病变。
  • 采用Fisher精确检验和χ2检验比较各方法恶性程度,并生成ROC曲线计算AUC以评估诊断效能及确定提示恶性的最佳SWE截断值。

关键影像表现/征象

  • ABVS图像上恶性组「回缩征」发生率显著高于良性组(P < .001)。

诊断标准与关键数值

  • BI-RADS分类的特异度88.72%、敏感度79.38%、阳性预测值83.70%、阴性预测值85.50%。
  • BI-RADS联合SWE-Max的特异度88.72%、敏感度92.78%、阳性预测值85.70%、阴性预测值94.40%。
  • BI-RADS+ABVS的敏感度95.88%、阴性预测值96.40%。
  • BI-RADS+ABVS+SWE的敏感度96.91%、特异度94.74%、阳性预测值93.10%、阴性预测值97.70%,为四项指标最高。

临床应用与阅片要点

  • 日常阅片中可在BI-RADS基础上联合ABVS观察「回缩征」及SWE测量SWE-Max,以提高诊断信心。
  • 联合应用可降低BI-RADS主观性,尤其有助于减少恶性病变漏诊(阴性预测值提高)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We herein compared the diagnostic accuracy of the BI-RADS, ABVS, SWE, and combined techniques for the classification of breast lesions.

METHODS: Breast lesions were appraised using the BI-RADS classification system as well as the combinations of BI-RADS plus ABVS (BI-RADS + ABVS) and BI-RADS plus SWE (BI-RADS + SWE), and both methods (BI-RADS + ABVS + SWE) by two specialties Medical Ultrasound physician. The Fisher's exact and χ2 tests were performed to compare the degree of malignancy for the various methods with a pathology ground truth. Receiver operating characteristic curves (ROC) were generated and the corresponding area under the curve (AUC) values were determined to test the diagnostic efficacy of the various methods and identify the optimal SWE cut-off indicative of malignancy.

RESULTS: The incidence of the retraction phenomenon on ABVS images of the malignant group was significantly higher (P < .001) than that of the benign group. The specificity, sensitivity, and positive and negative predictive values of the BI-RADS classification were 88.72, 79.38, 83.70, and 85.50%, respectively. BI-RADS plus SWE-Max exhibited enhanced specificity, sensitivity, and positive and negative predictive values of 88.72, 92.78, 85.70, and 94.40%, respectively. Similarly, when BI-RADS + ABVS was utilized, the sensitivity and negative predictive value increased to 95.88 and 96.40%, respectively. BI-RADS + ABVS + SWE possessed the highest overall sensitivity (96.91%), specificity (94.74%), and positive (93.10%) and negative (97.70%) predictive values from all four indices.

CONCLUSION: ABVS and SWE can reduce the subjectivity of BI-RADS. As a result, BI-RADS + ABVS + SWE resulted in the best diagnostic accuracy.

来源:J Ultrasound Med,查看原文。版权归原作者所有。