文献速递神经US

实时弹性成像诊断原发性开角型与假性剥脱性青光眼的可用性

Usability of Real-Time Elastography for the Diagnosis of Primary Open Angle and Pseudoexfoliation Glaucoma.
PubMed 文献 · J Ultrasound Med · 2022-12-19

本研究纳入30例POAG、30例PEX青光眼和30例年龄匹配对照,用实时弹性成像评估视乳头及视乳头周围结构的生物力学特性。POAG组眶脂肪与视乳头比值(ROFON)和眶脂肪与巩膜-脉络膜-视网膜复合体应变比(ROFSCR)高于PEX组,PEX组高于对照组;两指标与青光眼病程正相关,与MD、RPCVD及盘内血管密度负相关。实时弹性成像或为青光眼诊断和随访提供新视角。

要点

  • 实时弹性成像可定量视乳头及视乳头周围结构生物力学特性。
  • POAG组ROFON和ROFSCR高于PEX组,PEX组高于对照组。
  • ROFON和ROFSCR与青光眼病程正相关,与MD和血管密度负相关。

关键影像表现/征象

  • POAG组ROFON值高于PEX组(P = .008),ROFSCR值也高于PEX组(P = .004)。
  • PEX组ROFON值高于对照组(P = .012),ROFSCR值也高于对照组(P = .004)。
  • 两青光眼组中ROFON和ROFSCR与青光眼病程正相关,与MD、RPCVD和盘内血管密度负相关(P < .005;仅PEX组MD与ROFSCR相关P = .445)。

诊断标准与关键数值

  • 实时弹性成像测量指标:眶脂肪与视乳头比值(ROFON)和眶脂肪与巩膜-脉络膜-视网膜复合体应变比(ROFSCR)。

临床应用与阅片要点

  • 可关注视乳头及视乳头周围结构的实时弹性成像参数ROFON和ROFSCR。
  • ROFON和ROFSCR升高可能与青光眼病程进展及视野、血管密度恶化相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aims to investigate real-time elastography (RTE) use in the evaluation of the optic nerve head (ONH) and peripapillary structures for the diagnosis of primary open angle (POAG) and pseudoexfoliation (PEX) glaucoma.

METHODS: This case-controlled study included 30 patients with POAG, 30 patients with PEX glaucoma, and 30 age-matched control subjects. All of the participants underwent comprehensive ophthalmological examinations covering vessel density of optic nerve and retinal nerve fiber layer (RNFL) thickness measurements with optical cohorence tomography angiography and mean deviation (MD) measurements with Humphrey II Perimetry Visual Field Analyzer. In vivo evaluation of the biomechanical properties of the ONH and peripapillary structures were performed with RTE in all participants.

RESULTS: We observed higher ratios of orbital fat to optic nerve head (ROFON) values (P = .008) and strain ratios of orbital fat to scleral-choroidal-retinal complex (ROFSCR) values (P = .004) in the POAG group compared with PEX glaucoma group and higher ROFON (P = .012) and ROFSCR values (P = .004) in PEX glaucoma group than the control group. ROFON and ROFSCR values were positively correlated with glaucoma duration and negatively correlated with MD, radial peripapillary vessel density (RPCVD), and inside disc vessel density in both glaucoma groups (P < .005; only in the PEX glaucoma group for MD and ROFSCR, P = .445).

CONCLUSION: Determining the biomechanical properties of ONH and peripapillary structures with RTE in glaucomatous eyes may offer a new perspective on the diagnosis and follow-up of the progression of the disease.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Incekalan, Peköz. Usability of Real-Time Elastography for the Diagnosis of Primary Open Angle and Pseudoexfoliation Glaucoma. J Ultrasound Med. 2022. PMID: 36534582. doi:10.1002/jum.16157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。